Download Manual
Transcript
Appendix A Specifications IBLM Series General Specifications Control Characteristics Control System 1 RPM Output Speed Resolution 1 RPM Torque Characteristics Overload Endurance Operating Characteristics Accel/Decel Time 150% of rated current for 1 minute 0.2 to 15 seconds Communication By RS-485 External Signal By external terminals Operation Setting Signal Communication By RS-485 External Signal By external terminals Built-in Functions Environmental Conditions Starting torque can be 150% rated torque at 80RPM Speed Setting Protection Functions A-2 Sensorless Speed Setting Resolution Pollution Degree Installation Location Over voltage, over current, low voltage, motor overload, ground fault, drive overload and drive overheating Built-in AVR, 3 fault records, forward/reverse operation setting, output speed upper/lower limits, parameter reset, abnormal reset 2 Altitude 1,000 m or lower, indoor/outdoor (keep from corrosive gasses, liquid and dust) Ambient Temperature -40oC to 60oC (40oC for side-by-side mounting) Non-Condensing and not frozen Storage Temperature -40 oC to 70 oC Ambient Humidity Vibration 0 to 100% RH (non-condensing) 9.80665m/s2 (1G) less than 20Hz, 5.88m/s2 (0.6G) at 20 to 50Hz Revision Oct. 2010, IHE0