Appendix A Specifications IBLM Series
General Specifications
Control
Characteristics
Control System
1 RPM
Output Speed Resolution
1 RPM
Torque Characteristics
Overload Endurance
Operating
Characteristics
Accel/Decel Time
150% of rated current for 1 minute
0.2 to 15 seconds
Communication
By RS-485
External Signal
By external terminals
Operation
Setting
Signal
Communication
By RS-485
External Signal
By external terminals
Built-in Functions
Environmental Conditions
Starting torque can be 150% rated torque at 80RPM
Speed
Setting
Protection Functions
A-2
Sensorless
Speed Setting Resolution
Pollution Degree
Installation Location
Over voltage, over current, low voltage, motor overload, ground fault, drive
overload and drive overheating
Built-in AVR, 3 fault records, forward/reverse operation setting, output speed
upper/lower limits, parameter reset, abnormal reset
2
Altitude 1,000 m or lower, indoor/outdoor (keep from corrosive gasses, liquid
and dust)
Ambient Temperature
-40oC to 60oC (40oC for side-by-side mounting) Non-Condensing and not
frozen
Storage Temperature
-40 oC to 70 oC
Ambient Humidity
Vibration
0 to 100% RH (non-condensing)
9.80665m/s2 (1G) less than 20Hz, 5.88m/s2 (0.6G) at 20 to 50Hz
Revision Oct. 2010, IHE0