Transcript
Digital module requirement specification 2-31 Features: • • • • • • • • • • • • • • • Two command interfaces o ALTRO bus interface o Special I2C interface I2C interface is robust with timeout counters and masking of bus input when active transaction to other card. Setting of DACs for bias voltage for High Voltage region Interface to 3 ADCs for verifying voltage and current-levels as well as temperatures. Programmable min/and max thresholds for flagging errors in ADC values. Possible to set how to treat the voltages read back for current calculations: o Store them as is o diff with previous adc value. o Control the order of diff after the expected direction of the current Unlock register for write to read-only registers Monitoring error inputs from Power Regulators Interrupt line to RCU for errors of a severity level craving urgent measures Configurable number of threshold violations from 1 to 3 before interrupt is flagged. Possible to set the FEC in standby mode by turning off voltage regulators and not reporting any warnings/errors. Radiation precautions: o Hamming coded ADC threshold settings o Hamming coded DAC values o TMR of configuration/status registers and threshold config registers Configurable automatic update of DACs Event-length Manager module that generates a hitmap of all ALTRO channels and clocks this out to RCU by controlling dstb for Sparse Readout Mode. Debug registers to test ALTRO bus integrity PHOS BC specification_v3.4.doc Created by Johan Alme