Download "user manual"

Transcript
28: PID INSTRUCTION
Configure parameters 2 through 5 when data register is selected as the process variable.
2. Device Address
Shows the start data register (S1+0) of the control registers configured on the device tab when Data Register is specified as
the process variable (1).
3. Data Type
Select the process variable (S1+0) processing unit. Either W (word) or I (integer) can be selected.
4. Maximum Value, 5. Minimum Value
When Data Register is specified as the Process Variable (1), configure the range of input settings (process variable, high alarm
value, low alarm value) and control settings (set point, AT bias) in PID control with the maximum and minimum values. The
maximum value and minimum value can be configured within the range of the data type (3).
• When the data type is I (integer): -32,768 to +32,767.
• When the data type is W (word): 0 to 65,535
6. High Alarm Value (S1+3)
Set the upper limit value of the process variable.
If the process variable is higher than or equal to the high alarm value, the high alarm output (S1+3) turns on. If the process
variable is lower than the high alarm value, the high alarm output (S1+3) turns off.
The high alarm value can be set in the range between the low alarm value and the maximum input value.
7. Low Alarm Value (S1+4)
Set the lower limit value of the process variable.
If the process variable is lower than or equal to the low alarm value, the low alarm output (S1+4) turns on. If the process
variable is higher than the low alarm value, the low alarm output (S1+4) turns off.
The low alarm value can be set in the range between the minimum input value and the high alarm value.
8. Sampling Period (S1+5)
Set the cycle to execute the PID instruction. If the sampling period is set to a value shorter than the scan time, the PID
instruction is executed at each scan. If the sampling period is set to a value longer than the scan time, the interval between the
executions of PID instruction exceeds the sampling period. Exceeded period of time is deducted from the next sampling period.
The sampling period can be set from 0.01 to 100.00 seconds in 0.01 second increments.
Sampling period ≤ Scan time
PID instruction
executed
0msec
PID instruction
executed
PID instruction
executed
60msec
PID instruction
executed
120msec
180msec
PID instruction
executed
240msec
Scan time
(60ms)
0msec
80msec
160msec
240msec
Sampling period
(40ms)
PID control
executed
PID control
executed
PID control
executed
PID control
executed
PID control
executed
Sampling period: 80 ms, scan time: 60 mc (sampling period > scan time)
PID instruction
executed
0msec
PID instruction
executed
PID instruction
executed
60msec
120msec
PID instruction
executed
180msec
PID instruction
executed
240msec
Scan time
(60ms)
0msec
80msec
160msec
240msec
Sampling period
(40ms)
PID control
executed
PID control
executed
PID control
executed
PID control
executed
The PID instruction is not executed at each scan. The PID instruction is executed at the scan immediately after the sampling
time has elapsed.
28-4
SMARTAXIS LADDER PROGRAMMING MANUAL FT9Y-B1382