Download User manual
Transcript
7. Replace the lampholder in the housing, making sure that the edge with the semicircular cutout in its center faces out towards the edge of the and reinstall the four screws. Close the lamp cover, checking that no wires are trapped, and replace the lamp cover screw. 8. Reapply power. Discharge lamp adjustment The discharge lamp alignment can be adjusted to optimize the projected image using the adjustment screws on the lampholder (see illustration on right). Experiment with turning the screws until the brightest part of the beam is centered in the projected images. Lamp adjustment Lamp adjustment Lamp adjustment Replacing the main fuse Mania EFX fixtures use a slow-blow fuse for protection against current overload. An indication that the fuse may have blown is that when power is applied and the lamp is switched on, no light is produced. If the fuse blows repeatedly, there is probably a fault. Disconnect the fixture from power and data and contact a Martin service technician. Never bypass the fuse or replace it with one of another type or rating. To replace the main fuse: 1. Disconnect the power cable. 2. Pry open the fuse holder next to the power cable inlet with a flat-head screwdriver and remove the fuse. 3. Replace the fuse with one of the same type and rating. Fuse ratings are listed on serial number labels and under “Electrical” on page 50. 4. Replace the fuse holder before reapplying power. Service and maintenance 31