Download PProg User`s Manual
Transcript
This Manual describes the setup, interface, and operation of PProg software of version 3.00 which is intended for security managers to program S2000/S2000M fire and alarm consoles. Please read all the instructions completely before programming the S2000/S2000M console and save this Manual for further references The terms below are used throughout this manual: Alarm Loop (or Loop, or LP): The “alarm loop” is the same as the “initiating device circuit”, that is, an electrical circuit connected to a monitored input of an Orion system device, this circuit some conventional fire or intrusion detectors being brought in. A response of any single detector brought into the alarm loop causes the entire loop to response, so, the accurate location of the detector within the loop can not be known Arm / Disarm: This means starting/cancelling monitoring for zone conditions and sending alarms when the condition are changed Authenticator: A means for users to be authenticated by the system to gain access to various system functions such as configuring, arming, disarming, releasing extinguishing agent, and so on. The console supports operating with such authenticators as PIN-codes entered from the console or keypads and various access devices presented to the system readers including iButtons and Proximity cards Centralized Relay Control: The control method when the console gathers the device status data, analyses them, and gives commands to activate system executive devices depending on the logic programmed in the console database. In such a case the zones monitored by the console and the executive outputs controlled by this one can be parts of different devices Local Relay Control: The control method when a device monitors statuses of its own input zones, analyses these data, and activates its own relay outputs depending on the local logic programmed in its configuration Network Address: A unique number ranged from 1 to 127 of the device within the Orion ISS local RS-485 network Partition: A set of zones that are controlled as a whole. As a rule, zones fall into partitions depending on their location (e.g., a partition can involves all zones on an individual area) Zone: A minimal physical part or behavior aspect of a device in a security and safety installation that can be monitored and controlled independently. Depending on the context, the term “zone” can mean an alarm loop, an addressable detector in an S2000-KDL polling loop, a device circuit of an addressable input module, a reader input, a device input, status of the device itself, and so on