Download Manual - Amazon Web Services
Transcript
The operation state register's bit meanings are: Bit Meaning 0 Calculate the new demarcation coefficient 1 Waiting for a trigger signal 2 Remote control state (1 means enabled) 3 Output state (1 means ON) 4 Local key state (0 means not enabled, 1 means enabled) 5 Remote sensing mode (1 means enabled) 6 LOAD ON timer is enabled 7 Reserved The demand state register's bit meanings are: Bit Meaning 0 Reversed voltage is at instrument's terminals (1 means yes) 1 Over voltage (1 means yes) 2 Over current (1 means yes) 3 Over power (1 means yes) 4 Over temperature (1 means yes) 5 Not connect remote terminal 6 Constant current 7 Constant voltage 8 Constant power 9 Constant resistance 0x6A Get product's model, serial number, and firmware version Byte offset 3 to 7 Meaning ASCII model information 8 Low byte of firmware version number 9 High byte of firmware version number 10 to 19 Instrument's serial number in ASCII 20-24 Reserved 0x6B Read the bar code information Note: the bar code information is to be interpreted as ASCII data. 8500 DC Load Series Version: 031015 Page 69 of 77