Download Guard Door Locking Safety Function
Transcript
Safety Function Documents Door Locking and Monitoring Products: TLSZR-GD2 / Guardmaster® Safety Relays Safety Rating: PLe, Cat. 4 to EN ISO 13849.1 2008 Table of Contents: Introduction 6-30 Important User Information 6-30 Safety Function Realization 6-30 General Safety Information 6-31 Bill of Material 6-32 Electrical Schematic 6-33 Configuration 6-34 Calculation of the Performance Level 6-35 Verification and Validation Plan 6-39 Additional Resources 6-42 NHP Safety Reference Guide > Safety Function Documents: GSR 6B-31