Download Operations Plans

Transcript
SMART Dispersant Module
Attachment 13
v. 1/2000
3 . 1 3 Dispersant Monitoring Water Sampling
3 . 1 3 . 1 . Purpose
Collection of water samples during Tier II and III monitoring should assist in correlating
fluorometer readings in the field to actual dispersed oil concentrations in the water column.
The water samples, collected post-fluorometer (i.e., at the outlet port of the water conduit,
after it passes through the fluorometer cell) into a one-liter bottle, are analyzed at a
laboratory at the end of the field operation to ascertain actual oil concentrations in the water.
The guidelines provided below are general, and should serve as an initial starting point for
water sample collection. The number of samples collected may vary, depending on the
operation and the need for verification.
3 . 1 3 . 2 . Guidelines
3.13.2.1 Equipment
1. Certified pre-cleaned amber 500-ml bottles with Teflon™-lined caps.
•
For Tier II, a minimum of six bottles is required.
•
For Tier III, a minimum of thirteen bottles is required.
2. Labels for bottles documenting time and location of collection.
3. Observation notes corresponding fluorometer readings to water sample collection, and
any other observations.
3.13.2.2 Procedure
1. Open valve for water sample collection and allow water to run for ten seconds before
opening and filling the bottle.
2. Fill the bottle to the top and allow no headspace in bottles after sealing.
3. Label bottle with exact time of initial filling from the fluorometer clock as well as
sampling depth, transect, and the distance of water hose from the outflow port of the
fluorometer to the actual collection point of the water sample (to account for residence
time of water in the hose)
4. Store filled bottles in a cooler with ice while on the monitoring vessel. Keep
refrigerated (do not freeze) after returning to shore and send to the laboratory as soon
as possible.
5. Measure and record the length of the hose between the fluorometer outlet and the bottle
end, hose diameter, and flow rate (by filling a bucket). This will assist in accurately
linking water sample results to fluorometer readings.
3.13.2.3 Number of Samples
1. Collect one water sample per monitoring depth during the background (no oil)
transect. The fluorometer readings prior to collection should be relatively constant.
2. Collect two samples per monitoring depth during the pre-dispersant monitoring (under
untreated oil slick). Try to collect water samples correlating with representative
fluorometer values obtained.
34