Download Capstone Project Document

Transcript
the setpoint, and the degree of system oscillation. Note that the use of the PID algorithm for
control does not guarantee optimal control of the system or system stability.
4.4.2 Using Fox-301A on System
Fox-301A is used to develop a prototype. On the system that uses Fox-301A to control,
we measure and record temperature, humidity on environment chamber. We test the
temperature, ranging from 20oC to 40oC and humidity, ranging from 20oC to 40oC .After
testing, we have the following chart.
Temperature/Humidity
43.00
42.50
42.00
41.50
Temperature
41.00
Humidity
40.50
40.00
39.50
39.00
0
1
2
3
4
5
6
7
8
9
10
11
4.4.3 Using PID on System
Arduino Uno is used to develop a testing system. On the system that uses PID to
control, we measure and record temperature, humidity on environment chamber. We test
the temperature, ranging from 20oC to 40oC and humidity, ranging from 20oC to 40oC
.After testing continuously, we use PID (2, 5, 1) to configure PID so that PID will be as
same as Fox-301A. After testing, we have the following chart.
Page | 68