5.2.7.2 Alerts void timedAlert(unsigned long timeout); Polls the real-time clock until a timeout occurs. The RCM4200 will be in a low-power mode during this time. Once the timeout occurs, this function call will enable the normal power source. The A/D converter oscillator will be disabled and enabled. PARAMETERS timeout is the duration of the timeout in seconds RETURN VALUE None. SEE ALSO brdInit void digInAlert(int dataport, int portbit, int value, unsigned long timeout); Polls a digital input for a set value or until a timeout occurs. The RCM4200 will be in a low-power mode during this time. Once a timeout occurs or the correct byte is received, this function call will enable the normal power source and exit. PARAMETERS dataport is the input port data register to poll (e.g., PADR). portbit is the input port bit (0–7) to poll. value is the value of 0 or 1 to receive. timeout is the duration of the timeout in seconds (enter 0 for no timeout). RETURN VALUE None. User’s Manual 53