NOTE
FOR CE INSTALLATIONS A
N6361EMI SUPPRESSION
BEAD IS REQUIRED.
4219
DIP SWITCH
FOR SETTING ADDRESS
AND ZONE A RESPONSE
REED (TAMPER) SWITCH
TAMPER JUMPER POSITION
4219 IN CABINET
(NOT TAMPER)
TB2
4-PIN CONSOLE PLUG
CONNECTIONS SAME
AS TB2
4219 REMOTE
(TAMPER PROTECTED)
ZONES A
2
3
B
4
6
5
C
8
7
E
D
9
11
10
G
F
3
4
3
2
TB1
1
GRN DATA OUT
TO CONTROL
BLK
(–) GROUND
4
(+) 12VDC
YEL DATA IN
FROM CONTROL
1
1
12
RED
2
TERMINATE EACH
PROGRAMMED ZONE
WITH 1000 OHM
END-OF-LINE RESISTOR
(EACH ZONE'S MAX.
LOOP RESISTANCE:
300 OHMS + EOL)
H
4219-SOC-V0
Figure 2. Summary of Connections
4219 ADDRESS SETTINGS
("—" means"OFF")
SWITCH
NUMBER
ON
➞
1
2
3
4
5
6
—
ON
7
8
9
10
—
ON
—
11
12
13
14
—
ON
—
ON —
—
ON ON
—
—
—
—
—
—
—
—
—
—
2
ON —
ON
—
ON
—
ON
➞
➞
➞
1 2 3 4 5
0
➞
OFF
3
ON ON
—
—
ON ON —
—
ON ON
4
ON ON ON ON
—
—
ON ON ON ON
5
ON ON ON ON ON ON ON ON —
—
—
—
—
—
15
DIP SWITCH: (WHITE AREAS DENOTE SWITCH HANDLES)
POSITIONS 2-5: DETERMINE ZONE EXPANDER'S ADDRESS.
CONSULT CONTROL'S INSTRUCTIONS FOR ADDRESS USE.
SWITCH SETTING SHOWN SET FOR ADDRESS "0".
POSITION 1: DETERMINES ZONE A's RESPONSE TIME:
ON = NORMAL (300MS) RESPONSE, SHOWN (AS SHIPPED).
OFF = FAST (10MS) RESPONSE TO AN OPEN.
Figure 3. DIP Switch Settings
SEE THE CONTROL PANEL’S INSTALLATION AND SETUP GUIDE FOR COMPLETE INFORMATION
REGARDING THE LIMITATIONS OF THE ENTIRE SECURITY SYSTEM.