7 Buffer Memory
FX3U-1PG User's Manual
7.3 Positioning Parameters
How to use an electronic gear
Some servo motors require pulse trains at 200 kHz or more (in calculation) in order to satisfy the rated
rotation speed. For example, the command pulse frequency required to operate the MR-JN Series servo
amplifier and HF-KN Series servo motor manufactured by Mitsubishi at the rated rotation speed of 3,000 rev/
min can be obtained as follows.
(Suppose that the electronic gear ratio is the initial value "1/1", the number of command input pulses per
revolution is the initial value "10,000".)
f0 = FBP × 100 ×
f0 = 10,000 ×
CDV
N0
×
CMX
60
3,000
×1
60
f0
: Command pulse frequency [Hz]
(open collector type)
CMX
: Electronic gear (numerator of command
pulse magnification)
CDV
: Electronic gear (denominator of command
pulse magnification)
N0
: Rotation speed of servo motor [rev/min]
f0 = 500,000 [Hz]
FBP×100 : Number of command input pulses per
revolution [PLS/REV]
However, because the input command pulse in the open collector type servo amplifier and the pulse output
from the FX3U-1PG is 200 kHz maximum, operation at 500,000 Hz is impossible.
In such a case, you should change the electronic gear in the servo amplifier.
The electronic gear can be obtained as follows.
CMX
N0 1
= FBP × 100 ×
×
CDV
f0
60
f0
: Command pulse frequency [Hz]
(open collector type)
CMX
3,000
1
= 10,000 ×
×
CDV
60
200,000
CMX
5
=
CDV
2
CMX
: Electronic gear (numerator of command
pulse magnification)
CDV
: Electronic gear (denominator of command
pulse magnification)
N0
: Rotation speed of servo motor [rev/min]
FBP×100 : Number of command input pulses per
revolution [PLS/REV]
The table below shows the setting of major electronic gears and pulse rates obtained by the above
calculation.
Rated rotation
speed of servo
motor
3,000 r/min
58
Servo amplifier
Maximum input pulse
frequency
200 kHz
(open collector)
Command pulse frequency (200 kHz)
Number of command
input pulses per
revolution
10,000 PLS/REV
Electronic gear
Pulse rate
5/2
50,000 PLS/REV
25/2
131,072 PLS/REV
4,096/125
4,000 PLS/REV