This function enables or disables recording of events when Exp(0) changes.
When enabled, any transition (up or down) on expansion connector bit 0 (DB-15
type connector, pin-1) will cause recording of a snapshot of the SCSI bus
(within 30 ns of the transition).
This mode is useful to relate the timing of
signals internal in tested system to the contents of the SCSI bus.
2.2.5.7
<6> - CAPTURE SCAM PROTOCOL
This mode allows recording of events during the auto-configuration process of
the SCSI-3 SCAM Protocol. In this mode, whenever both BSY and SEL signals are
active, transitions on D5, D6, or D7 (the SCAM Handshake lines) cause an event
to be recorded.
Since transitions on the certain data lines cause recording
(which in normal trace mode would be ignored), more of the trace memory is
used than in the normal trace mode.
The reader is referred to Appendix E and the SCSI-3 ANSI specification
(document: SCSI-3 Parallel Interface 'SPI', Annex B) for detailed description
of the SCAM protocol.
2.2.6
TRIGGER SETUP
Press the <Trig> key on the keypad to specify the trigger mode and conditions
of the trigger event. From the PC/AT keyboard, the <T> key is a selector for
this function.
See Section 5 for a complete discussion of the Trigger Setup Menu and
triggering.
2.2.7
<1> - CLEAR TRACE