1.3.7 Cooling Modules
Figure 1-13: Cooling Module
PN: IFT-9274CFanMod
The A24F subsystems come with two (2) hot swappable, redundant, dualfan cooling modules (shown in Figure 1-13) preinstalled in the subsystem.
Two (2) 8cm blowers are housed in each cooling module and provide
ventilation airflow from the front to the rear of the subsystem, extracting the
heat generated by the SATA hard drives and other components. The two (2)
cooling modules are installed directly above the PSUs. (See Figure 1-4)
Intelligent Dual Speed Operation
The cooling fans in the cooling module operate with two rotation speeds.
Under normal operating conditions, the cooling fans run at the low speed,
which is sufficient for maintaining efficient airflow across the components.
Under the following conditions, cooling fans raise their rotation speed to
increase the airflow:
1-12
1.
Component failure: if one cooling fan in a cooling module, a PSU,
or a temperature sensor fails, the remaining cooling fan(s)
automatically raises its rotation speed.
2.
Elevated temperature: if the temperature breaches the upper
threshold set for any of the interior temperature sensors, the cooling
fans automatically raise their rotation speed.
3.
During the subsystem initialization stage, the cooling fans operate
at the high speed and return to low speed once the initialization
process is completed and no erroneous condition is detected.