Mitochondrial DNA Analysis Protocol Mitochondrial DNA Analysis Protocol 2.wpd Issue Date: 3/26/08 Revision: 2 Page 12 of 89 2. The mtDNA analysis of a particular sample extract does not proceed if the amount of amplified mtDNA in the NC exceeds 10% of the amount of amplified mtDNA in the sample as assessed through CE quantification. 3. Samples may be re-amplified with new reagents should the amount of amplified mtDNA in the NC exceed 10% of the amount of amplified mtDNA in the sample or have sequence concordance with the sample. A new NC is included in the repeated amplification. 4. Regardless of the relative quantity of mtDNA in the NC, if the NC sequence is in concordance with the evidence sample, the results of the sample amplification reaction are not used for comparison purposes. For example, if the NC for region HV1A shows a sequencing result which is in concordance with an HV1A sample sequence, all HV1A sequences are not used for comparison purposes. The evidence sample sequence can be used under the following conditions: a) b) c) 5. the NC does not analyze; the NC analyzes but is not of requisite quality for comparison purposes; the NC sequence analyzes, but the sequence is not in concordance with the evidence sample and its quantity is less than or equal to 10% of that of the evidence sample. If analyzable mtDNA sequence is obtained from the negative control, an attempt is made to determine the source of this DNA. 2.5.3 Positive Control 1. The use of a positive control (see Appendix A) monitors the success of amplification, sequencing, and sequence analysis. 2. The record of the particular positive control used and its lot number is maintained for each case. 3. The mtDNA analysis of a particular sample extract is repeated, going back to the appropriate step, if the positive control fails to amplify and/or sequence correctly. 3 Procedures for DNA Extraction This section describes DNA extraction procedures from hair, body fluids and tissues, and calcified tissues (bones and teeth). Whenever possible, a portion of the sample will be retained. All extraction procedures are performed in dedicated laminar flow or AirClean hoods. This is an uncontrolled copy of document. a controlled doument. This is a controlled