Download Acorn FileStore E20 User guide
Transcript
2. Unplug each Communicator from Econet in turn, attempting a command such as *CAT after unplugging each one. You should get the Line jammed message each time until you unplug the Communicator that has the fault ie when the *CAT command works without the Line jammed message, the last Communicator you unplugged was the faulty one. Return the faulty Communicator to your supplier for repair. 3. If this does not isolate the fault, it is in the Econet cabling or FileStore itself. Shut FileStore down and try plugging a Communicator into it directly. If this works, there is a fault in your Econet cabling. Contact your supplier for help. 4. If this fails, contact your supplier to arrange further investigation and repair. Memory fault found The memory components in FileStore have a fault. Contact your supplier to arrange a repair. Net error There is a fault in the Econet cabling. Contact your supplier to arrange a repair. No clock The 'clock' signal which Econet uses to synchronise communications (rather like a metronome dictating the beat of a musical performance) is hot reaching the station. 1. Check that the station is plugged into Econet. 2. Check that FileStore is on and plugged into Econet. If these are not the problem, there is a fault in FileStore's clock unit. Contact your supplier to arrange a repair. No reply FileStore has stopped working part way through obeying a command. Check that FileStore is still turned on, plugged into Econet and in user mode. Not found A user has specified a file or directory that does not exist, usually. because they have mistyped the name, or do not know where it is. Use Appendix 2: DEALING WITH PROBELMS 67