Troubleshooting Display Cause Solution C1 Fan rotation too low on startup. (part# 8707204039) 1. Disconnect power supply cord. Check wire connections on back side of fan and the two large wire connectors on the control unit. Removal of lower access panel on control unit is necessary to access connectors. 2. Verify that supply voltage is 120VAC and is properly grounded. 3. Verify that venting meets specifications outlined in chapter 3.6. Long vent lengths, venting with more than three elbows, blocked vent or combination venting may cause this failure. Verify backdraft flapper inside flue gas collector is not stuck shut. 4. Check gas pressure. See chapter 3.8. Low gas pressure may cause the fan to change its speed to meet desired temperature. 5. Possible defective control unit. Call Bosch Water Heating for further instructions. C6 Fan rotation too low in operation (part# 8707204039) 1. Disconnect power supply cord. Check wire connections on back side of fan and the two large wire connectors on the control unit. Removal of lower access panel on control unit is necessary to access connectors. 2. Check supply voltage is 120VAC and is properly grounded. 3. Verify that venting meets specifications outlined in chapter 3.6. Long vent lengths, venting with more than three elbows, blocked vent or combination venting may cause this failure. Verify backdraft flapper inside flue gas collector is not stuck shut. 4. Ensure intake and exhaust terminations maintain the required clearances stated in the manual ( Fig. 17 and Table 6 on page 17). Cross contamination between intake and exhaust may cause the fan to alter its rotational speed. 5. Check gas pressure. See chapter 3.8*. Low gas pressure may cause the fan to change its speed to meet desired temperature. 6. Possible defective control unit. Call Bosch Water C7 No rotational speed sensor from fan. (part# 8707204039) 1. Disconnect power supply cord. Check wire connections on back side of fan and the two large wire connectors on the control unit. Removal of lower access panel on control unit is necessary to access connectors. 2. Check supply voltage is 120VAC and is properly grounded. 3. Possible defective component in fan. Call Bosch Water Heating for further instructions. CA Water flow signal over specified maximum value. (part# 8708505016) 1. Disconnect power supply cord and check wire connections on water valve and the two connectors on the control board. 2. Excessive water pressure and flow. Ensure water pressure is less than 150psi and flow rate is less than 10 gallons per minute. Table 12 * By installer or service technician only. 6 720 608 263 37