Functions, monitoring, and protective functions 9.5 Monitoring and protective functions 9.5.2 Thermal monitoring and overload responses Description The priority of thermal monitoring for power components is to identify critical situations. If alarm thresholds are exceeded, the user can set parameterizable response options that enable continued operation (e.g. with reduced power) and prevent immediate shutdown. The parameterization options, however, only enable intervention below the shutdown thresholds, which cannot be changed by the user. The following thermal monitoring options are available: ● i²t monitoring – A07805 – F30005 i²t monitoring is used to protect components that have a high thermal time constant compared with semi-conductors. Overload with regard to i²t is present when the converter load (r0036) is greater than 100% (load in % in relation to rated operation). ● Heatsink temperature – A05000 – F30004 Monitoring of the heat-sink temperature (r0037) of the power semi-conductor (IGBT). ● Chip temperature – A05001 – F30025 Significant temperature differences can occur between the barrier layer of the IGBT and the heatsink. These differences are taken into account and monitored by the chip temperature (r0037). If an overload occurs with respect to any of these three monitoring functions, an alarm is first output. The alarm threshold p0294 (i²t monitoring) can be parameterized relative to the shutdown (trip) values. Example The factory setting for the alarm threshold for chip temperature monitoring is 15 Kelvin (K), and 5 K for the heat sink and inlet air. This means that the "Overtemperature, overload" alarm is triggered at 15 K or 5 K below the shutdown threshold. The parameterized responses are induced via p0290 simultaneously when the alarm is output. Possible responses include: ● Reduction in pulse frequency (p0290 = 2, 3) This is a highly effective method of reducing losses in the power unit, since switching losses account for a high proportion of overall losses. In many applications, a temporary reduction in the pulse frequency can be tolerated to allow the process to continue. Disadvantage: As a result of the pulse frequency reduction, the current ripple is increased which can mean that the torque ripple is increased at the motor shaft (for low moments of inertia) and also an increased noise level. Reducing the pulse frequency does not affect the dynamic response of the current control circuit, since the sampling time for the current control circuit remains constant. 406 Drive converter cabinet units Operating Instructions, 10/2008, A5E00288214A
Related documents
Operating Instructions
Operating Instructions
A1 Control Workplace Hazards - SOL*R
Istruzioni per l`uso
Operating Instructions
Istruzioni per l`uso
Conversores de frequência montados em unidade de
Conversores de frequência montados em unidade de
Siemens SINAMICS G150 Specifications
Siemens SINAMICS G150 Specifications