Download Installation, Service and User Instructions (French version

Transcript
Electrical connection
The connection of the hobs to mains is effected via the flex and the three pin plug located underneath the
hotplate. The appliance operate at a main voltage of 120V a.c., frequency 60Hz. Electric power absorption is
about 1W for 5 gas burner version or 2W for 6 gas burners version.
WARNING: Electrical Grounding Instructions: This appliance is equipped with a (three-prong)
grounding plug for your protection against shock hazard and should be plugged directly into a
properly grounded receptable. Do not cut or remove the grounding prong from this plug.
Wiring diagrams
Wiring diagram description
For hotplate model A see Fig. 11.
For hotplate model B see Fig. 12.
1. Cable terminal
2. Ignition switch
3. Spark generator
4. Ignition spark
L. Black
N. White
T. Green (earth)
Room ventilation – Location and venting.
ATTENTION: An exhaust fan may be used with the appliance; in each case it shall be installed in
conformity with the national standards in force.
ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be
installed in conformity with the national standards in force.
Conversion to different types of gas
Before carrying out any maintenance work, disconnect the appliance from the gas and electric
supply. For Natural Gas fit regulator assembly described in Fig. 5. For LP Gas fit assembly described
in fig. 5.
- CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS:
To change the nozzles of the burners use the following procedure:
Lift up the burners and unscrew the nozzles ( Fig. 7) using an adjustable spanner of 7 mm and change the
nozzles with those designed for the new gas supply according to the information given in TABLE A shown
below.
TABLE A: Adapting to different types of gas
Drop-in cooktop with 5 workyop burners model B3W0..U4X(2 or 5)D
Burner
Position
Auxiliary
Front R
Semi-Rapid
Rear L
Rear R
Front L
Rapid
Centre Inner
Dual
burner
Centre Outer
Inj. size
1/100mm
0,90
0,54
1,18
0,70
1,55
0,92
0,80
0,49
N°2 x 1,15
N°2 x 0,70
Gas
Type
NG
LP(Propane)
NG
LP(Propane)
NG
LP(Propane)
NG
LP(Propane)
NG
LP(Propane)
Pressure
[i.w.c.]
4”
11”
4”
11”
4”
11”
4”
11”
4”
11”
Max Rate
[BTU/h]
[W]
3400
996
3400
996
6100
1787
6100
1787
10400
3047
10400
3047
2800
820
2800
820
12000
3516
12000
3516
Min Rate
[BTU/h]
[W]
900
264
900
264
1500
439
1500
439
3700
1084
3700
1084
900
264
900
264
5300
1553
5300
1553
By-pass size
[1/100mm]
Regulated
0,29
Regulated
0,37
Regulated
0,58
Regulated
0,29
Regulated
0,73
Drop-in cooktop with 6 workyop burners model B3Y0..U4X(2 or 5)D
Burner
Position
Auxiliary
Front R
Semi-Rapid
Rear L & C
Front C
Front L
Rapid
Centre Inner
Dual
burner
Centre Outer
Inj. size
1/100mm
0,90
0,54
1,18
0,70
1,55
0,92
0,80
0,49
N°2 x 1,15
N°2 x 0,70
Gas
Type
NG
LP(Propane)
NG
LP(Propane)
NG
LP(Propane)
NG
LP(Propane)
NG
LP(Propane)
Pressure
[i.w.c.]
4”
11”
4”
11”
4”
11”
4”
11”
4”
11”
Max Rate
[BTU/h]
[W]
3400
996
3400
996
6100
1787
6100
1787
10400
3047
10400
3047
2800
820
2800
820
12000
3516
12000
3516
CAUTION: save the orifices removed from the appliance for future use
5
Min Rate
[BTU/h]
[W]
900
264
900
264
1500
439
1500
439
3700
1084
3700
1084
900
264
900
264
5300
1553
5300
1553
By-pass size
[1/100mm]
Regulated
0,29
Regulated
0,37
Regulated
0,58
Regulated
0,29
Regulated
0,73