Download ADTRAN 612 User manual
Transcript
Total Access 600 Series T1 TDM IAD UIG/64200681L1-31B Page 45 Managing the Modules – Modules Use the 02'8/(6menu to view and set the parameters shown in Figure 12. The Total Access 600 contains four integrated modules: The WAN/Network interface, FXS, Echo Canceller/ADPCM module, and the V.35 interface. The 02'8/(6 table allows management of the on-board modules in the Total Access 600. The table contains 0(18, $/$50, 7(67, and 67$786 indicators/menus customized for each module. Figure 12. Modules Menu >NET (T1) Menu Format Sets the frame format for the T1 interface. The setting must match the frame format of the circuit to which the interface is connected. Choices are (6) (extended superframe), 6) (superframe), or 6/& $/$50 or6/&$/$50. 6) is equivalent to the D4 frame format. Line Code Sets the line code for the T1 interface. The setting must match the line code of the circuit to which the interface is connected. Choices are %=6 (bipolar with 8-zero substitution) or $0, (alternate mark inversion). © 2002, ADTRAN, Inc. Total Access 600 Series User Manual