International English 2.3 2. INSTALLATION Mechanical Installation ! Warning THIS EQUIPMENT MUST BE GROUNDED. ♦ To ensure the safe operation of the equipment, it must be installed and commissioned by qualified personnel in full compliance with the warnings laid down in these operating instructions. ♦ Take particular note of the general and regional installation and safety regulations regarding work on dangerous voltage installations (e.g. EN 50178), as well as the relevant regulations regarding the correct use of tools and personal protective gear. ♦ The mains input, DC and motor terminals, can carry dangerous voltages even if the inverter is inoperative; wait 5 minutes to allow the unit to discharge after switching off before carrying out any installation work. 4 Frame Size A: Fixing with 2 bolts M4 2 nuts M4 2 washers M4 55 mm 0.22" 160 mm 173 mm 6.30" 6.81" 73 mm 149 mm 2.87" 5.87" 160 mm 6.30" Tightening torque (unit to cabinet) with washers fitted: 2.5 Nm Connecting to DIN rail Ø 4.5 mm 0.17" Frame Size B: Ø 4.8 mm 0.19" 202 mm 174 mm 7.95" 6.85" Fixing with 4 bolts M4 4 nuts M4 4 washers M4 Tightening torque (unit to cabinet) with washers fitted: 2.5 Nm 149 mm 172 mm 138 mm 5.87" 6.72" 5.43" Frame Size C: Fixing with 4 bolts M5 4 nuts M5 4 washers M5 Ø 5.5 mm 0.22" 204 mm 8.03" 245 mm 9.65" 185 mm 195 mm 7.28" 7.68" Figure 2-1 20 Tightening torque (unit to cabinet) with washers fitted: 3 Nm 174 mm 6.85" Drill pattern for MICROMASTER 420 MICROMASTER 420 Operating Instructions 6SE6400-5AA00-0BP0