Download RAD Data comm LRS-24 Specifications
Transcript
Chapter 4 Troubleshooting and Diagnostics This chapter discusses: • Types of loopback tests • Internal BERT operation • Setting loopback, BER, and LED tests • Viewing alarm status • Viewing alarm buffer messages • Troubleshooting. All diagnostics options can be implemented from an ASCII terminal or from an SNMP management tool. The LLB and REM loopbacks can also be initiated from the DTE via dedicated pins of the DCE connector. These diagnostic approaches can also be used in combination. For example, the BERT circuit test pattern can be run on a path determined by one of the loopback connections and then examine the alarm buffer messages for any transmission error or configuration mismatch. 4.1 Loopback Tests Three loopback connections apply to a transmission system consisting of an ASM-40CD local module and an ASM-40 remote unit. ASM-40CD Ver. 1.0 • Local analog loopback – The analog transmit signal from the local unit transmitter is looped back to the local unit receiver. The loopback tests the local ASM-40CD modem, the local DTE and the connections between them. The loopback is set from the local DTE via the LLB control line (see Figure 4-1). • Local digital loopback – The digital receive signal is looped back in the local ASM-40CD towards the line. The loopback tests the local ASM-40CD, the remote DTE and the line between them (see Figure 4-3). • Remote digital loopback – The digital receive signal is looped back in the remote ASM-40 towards the line. The loopback tests the local ASM-40CD, the remote ASM-40 and the line between them. The loopback is set from the local ASM-40CD or from the local DTE via the RLB control line (see Figure 4-2). Loopback Tests 4-1