APPENDIX A - VFD CENTRIFUGE HMI SERVER SYSTEM
Figure A-14. DeskLock Screen
Troubleshooting Network Connectivity
The following IP addresses of all system components permit entry into the router configuration to
verify that the router is communicating:
Router 1
Router 2
Router 3
Router 4
HMI Server PC
Activation PLC
X1 WAN Port
https://100.100.10.1
https://100.100.10.2
https://100.100.10.3
https://100.100.10.4
LAN Port #1
100.100.10.101
100.100.10.100
X2 LAN Port
https://100.100.100.101
https://100.100.100.101
https://100.100.100.101
https://100.100.100.101
LAN Port #2
Assigned by DHCP
Use the following Network Address Translation (NAT) data to verify that connections are correct
and that communication is established between the PLC and routers:
X1 WAN Port of Router
X2 LAN Port of Router
PLC 1
100.100.10.10
100.100.100.10
PLC 2
100.100.10.20
100.100.100.10
PLC 3
100.100.10.30
100.100.100.10
PLC 4
100.100.10.40
100.100.100.10
To assist in troubleshooting communication defects, a customer PC may be connected as shown
in Figure A-15 to ping the routers to verify communication.
15 May 13
A-9
Appendix A-HMIServerSystem