Download Amana GDS8 Operating instructions
Transcript
SERVICING A Gas Valve On/Off Selector Switch INLET GAS STREAM B Inlet Pressure Tap (Side of Valve) Pressure Regulator Adjustment (Under Cap Screw) The length of Dimension "A" determines the angle of Gas Stream "B". Gas Valve On/Off Selector Switch GAS STREAM B S-307 CHECKING GAS PRESSURE Gas Supply Pressure Measurement Outlet (Manifold) Pressure Tap White-Rodgers Model 36F22 DENT OR BURR A dent or burr will cause a severe deflection of the gas stream. OUTLET Inlet Pressure Tap INLET OUTLET Pressure Regulator Adjustment (Under Cap Screw) Outlet Pressure Tap White-Rodgers Model 36G22 CAUTION TO PREVENT UNRELIABLE OPERATION OR EQUIPMENT DAMAGE, THE INLET GAS SUPPLY PRESSURE MUST BE AS SPECIFIED ON THE UNIT RATING PLATE WITH ALL OTHER HOUSEHOLD GAS FIRED APPLIANCES GAS VALVE CONTROL ON/Off SWITCH OPEN TO ATMOSPHERE OPERATING. INLET WR O F F M 1 P 3 C 2 ON INLET PRESSURE TAP SIDE OF VALVE) Gas inlet and manifold pressures should be checked and adjusted in accordance to the type of fuel being consumed. The line pressure supplied to the gas valve must be within the range specified below. The supply pressure can be measured at the gas valve inlet pressure tap or at a hose fitting installed in the gas piping drip leg. The supply pressure must be measured with the burners operating. To measure the gas supply pressure, use the following procedure. OUTLET OUTLET (MANIFOLD) PRESSURE TAP (SIDE OF VALVE) MANOMETER HOSE PRESSURE REGULATOR ADJUSTMENT (UNDER CAP SCREW) MANOMETER Measuring Inlet Gas Pressure White Rodgers 36E (Gas Valve Tap) WARNING DISCONNECT ELECTRICAL POWER AND SHUT OFF GAS SUPPLY. 1. After turning off gas to furnace at the manual gas shutoff valve external to the furnace, remove burner compartment door to gain access to the gas valve. 2. Connect a calibrated water manometer (or appropriate gas pressure gauge) at either the gas valve inlet pressure tap or the gas piping drip leg as shown in the following figures. NOTE: At either location, a hose fitting must be installed prior to making the hose connection. 119