Download Amana GDS8 Operating instructions

Transcript
SERVICING
A
Gas Valve
On/Off
Selector
Switch
INLET
GAS
STREAM B
Inlet Pressure Tap
(Side of Valve) Pressure Regulator
Adjustment
(Under Cap Screw)
The length of Dimension "A" determines the angle of Gas
Stream "B".
Gas Valve
On/Off
Selector
Switch
GAS
STREAM B
S-307 CHECKING GAS PRESSURE
Gas Supply Pressure Measurement
Outlet (Manifold)
Pressure Tap
White-Rodgers Model 36F22
DENT OR
BURR
A dent or burr will cause a severe deflection of the gas
stream.
OUTLET
Inlet Pressure
Tap
INLET
OUTLET
Pressure Regulator
Adjustment
(Under Cap Screw)
Outlet Pressure
Tap
White-Rodgers Model 36G22
CAUTION
TO PREVENT UNRELIABLE OPERATION OR EQUIPMENT DAMAGE, THE
INLET GAS SUPPLY PRESSURE MUST BE AS SPECIFIED ON THE UNIT
RATING PLATE WITH ALL OTHER HOUSEHOLD GAS FIRED APPLIANCES
GAS VALVE CONTROL
ON/Off SWITCH
OPEN TO
ATMOSPHERE
OPERATING.
INLET
WR
O
F
F
M
1
P
3
C
2
ON
INLET PRESSURE TAP
SIDE OF VALVE)
Gas inlet and manifold pressures should be checked and
adjusted in accordance to the type of fuel being consumed.
The line pressure supplied to the gas valve must be within
the range specified below. The supply pressure can be measured at the gas valve inlet pressure tap or at a hose fitting
installed in the gas piping drip leg. The supply pressure
must be measured with the burners operating. To measure
the gas supply pressure, use the following procedure.
OUTLET
OUTLET (MANIFOLD) PRESSURE TAP
(SIDE OF VALVE)
MANOMETER HOSE PRESSURE REGULATOR ADJUSTMENT
(UNDER CAP SCREW)
MANOMETER
Measuring Inlet Gas Pressure
White Rodgers 36E
(Gas Valve Tap)
WARNING
DISCONNECT ELECTRICAL POWER
AND SHUT OFF GAS SUPPLY.
1. After turning off gas to furnace at the manual gas shutoff
valve external to the furnace, remove burner compartment door to gain access to the gas valve.
2. Connect a calibrated water manometer (or appropriate
gas pressure gauge) at either the gas valve inlet pressure tap or the gas piping drip leg as shown in the following figures.
NOTE: At either location, a hose fitting must be installed
prior to making the hose connection.
119