Download Creator Electronics CR-M4102 Specifications

Transcript
(3) Program example
1) JOG operation conditions
Item
Condition
Axis used
JOG operation speed
2)
Axis 1
Axis 2
1500mm/min
1500mm/min
SFC program example when axis 1 and axis 2 are started simultaneously
JOG operation
SFC program No. 10
All JOG operation is
stopped when the JOG
operation mode is not
selected.
Start of JOG
operation mode
END
[Simultaneous start]
The JOG operation command is issued at
speed of 1,500mm/min when one of the 2-axis
simultaneous start switches (X0, X2, X6, X8)
is turned ON.
[X2: axis 1, axis 2: Forward]
[X6: axis 1, axis 2: Reverse]
[X0: axis 1: Reverse, axis 2: Forward]
[X8: axis 1: Forward, axis 2: Reverse]
The JOG operation is executed at JOG
simultaneous command flag ON when one of
the X0, X2, X6 and X8 switches is turned ON.
[Transition]
[Operation control
step]
The simultaneous JOG operation is stopped
when the switches (X0, X2, X6 and X8) are all
turned OFF.
G110
PX2 * !PX6 * !PX0 * !PX8
G112
PX0 * !PX2 * !PX6 * !PX8
G114
!(PX2 + PX6 + PX0 + PX8)
F100
RST M3202
RST M3203
RST M3222
RST M3233
RST M2048
F110
D710 = H0000
D712 = H0003
D640L = K150000
D642L = K150000
F112
D710 = H0001
D712 = H0002
D640L = K150000
D642L = K150000
F114
SET M2048
G111
PX6 * !PX2 * !PX0 * !PX8
G113
PX8 * !PX2 * !PX6 * !PX0
G115
PX2 + PX6 + PX0 + PX8
F109
D710 = H0003
D712 = H0000
D640L = K150000
D642L = K150000
F111
D710 = H0002
D712 = H0001
D640L = K150000
D642L = K150000
F113
RST M2048
F115
RST M2048
10 - 17