Download Dimplex AWP 300 LW Technical data
Transcript
2.3 Safety Devices The HPWH is equipped with the following safety features: 2.3.1 High-Pressure Pressostat (HP) The high-pressure pressostat protects the heat pump from excessive operating pressures in the refrigeration cycle. In the case of a malfunction, the pressostat switches off the heat pump. The heat pump is restarted automatically as soon as the pressure in the refrigeration cycle has dropped to an acceptable level. 2.3.2 Safety Temperature Limiter for Immersion Heater (STL) Partition The STL protects the hot water installation from excessive temperature increases. It is secured to the switch box panel, and the associated sensor is located in the well of the immersion heater. STL When the preset switching value (99 °C) is exceeded, the immersion heater is switched off. The immersion heater cannot be restarted unless the hot water temperature has fallen to ≤ 90 °C and the reset button (Fig. 2) on the STL has subsequently been pressed. 85° B3 F2 30° Reset button Operating panel Important Note! Bild 2 : STB - The safety temperature limiter can be accessed after the operating panel has been removed. Any interventions may therefore only be performed by qualified persons. Prior to opening the unit, the appliance must be disconnected from the power supply! 3. Controlling and Operating Concept 3. 1 Operating Panel of HPWH Analog display of hot water temperature 'Heat pump' switch 'Immersion heater' switch 'Heat exchanger' switch Hot water temperature dial Fig. 3: Operating panel of HPWH Page 5 of 20