Download Microtech PCD-47-PC Specifications
Transcript
VLT® HVAC Drive FC 102 Design Guide Start Event 1 True (1) command Action 1 Select Preset (10) 130BA148.11 Application Examples State 0 Stop command Event 2 On Reference (4) Action 2 Start Timer (29) State 1 Event 4 False (0) Action 4 No Action (1) 6 6 State 2 Event 3 Time Out (30) Action 3 Select Preset ref. (11) Illustration 6.6 Set Actions Set the Smart Logic Control in LC-00 Logic Controller Mode to ON. A start/stop command is applied on terminal 18. If stop signal is applied the frequency converter will ramp down and go into free mode. 130BA362.10 6.1.8 BASIC Cascade Controller Constant Speed Pumps (2) Variable Speed Pumps (1) Motor starter Pressure Sensor Frequency Converter with Cascade Controller Illustration 6.7 BASIC Cascade Controller The BASIC cascade controller is used for pump applications where a certain pressure (“head”) or level needs to be maintained over a wide dynamic range. Running a large pump at variable speed over a wide range is not an ideal solution because of low pump efficiency and because there is a practical limit of about 25% rated full load speed for running a pump. 158 In the BASIC cascade controller, the frequency converter controls a variable speed motor as the variable speed pump (lead) and can stage up to 2 additional constant speed pumps on and off. By varying the speed of the initial pump, variable speed control of the entire system is provided. This maintains constant pressure while eliminating pressure surges, resulting in reduced system stress and quieter operation. Fixed Lead Pump The motors must be of equal size. The BASIC cascade controller allows the frequency converter to control up to 3 equal size pumps using the two built-in relays. When the variable pump (lead) is connected directly to the drive, the other 2 pumps are controlled by the 2 built-in relays. When lead pump alternations is enabled, pumps are connected to the built-in relays and the frequency converter is capable of operating 2 pumps. Lead Pump Alternation When the motors are of equal size, lead pump alteration enables the frequency converter to cycle the drive between the pumps in the system (maximum of 2 pumps). In this operation, the run time between pumps is equalized, reducing the required pump maintenance and increasing reliability and lifetime of the system. The alternation of the lead pump can take place at a command signal or at staging (adding another pump). The command can be a manual alternation or an alternation event signal. If the alternation event is selected, MG16C102 - Rev. 2013-08-20