Download Worcester ZB 7-28 HE system Technical data
Transcript
Maintenance 8 Maintenance B Always disconnect the appliance from the electrical power supply (fuse, circuit breaker) before carrying out any work on the electrical systems or components. B Always turn off the gas cock before carrying out any work on components which carry gas. i There is a special Service booklet for the Engineer, order no. 7-181-465-346, available to competent persons. i All safety and control systems are monitored by the Bosch Heatronic. In the event of a component fault, the display shows a fault code. B The User should be recommended to have the appliance serviced regularly by a competent person (see Maintenance Contract). B Use only genuine spare parts B Refer to the Spare Parts List when ordering spare parts. B Always renew seals and O-rings removed during servicing or repair work. B Use only the following types of grease: – Water valve: WRAS approved silicon based grease – Unions: approved sealant. B To drain the appliance shut the system valves and open the pressure relief valve. B To drain the appliance shut the system valves and open the pressure relief valve. B Upon completion of any electrical work check for earth continuity, correct polarisation and resistance to earth. 6 720 611 443 GB (03.11) 33