Release notes: SIMPL Release notes:
z
Page 101 of 103
Fix problem with Application Builder generated programs - when opening the SMW file in SIMPL, there was
potential to get a "User Lock" error.
Fixes/Changes from 2.00.23 to 2.00.24 (2.00.24: Internal Release Only)
z
z
z
In prior versions, opening a SIMPL+ module from SIMPL (right click on the module in your program and choose
"Edit User Module") or a SIMPL module (right click on the module in your program and choose "Edit User Module"
and then "In New Instance") and saving the file (with your original program still open in the first instance of SIMPL)
would sometimes cause the modules within your main program to get randomly reassigned as other modules. This
has been fixed.
Fixed problem with Search/Replace not working: When the search and/or replace strings were single digit numbers,
they were being turned into underscores.
SIMPL+: Fix for 2 Series system crashing when an out of bounds array write was performed. The 2 Series system
will now issue an error message about the out of bounds array.
Fixes/Changes from 2.00.22 to 2.00.23 (2.00.23: Internal Release Only)
z
z
z
Fix so that uninstalling or running this version (or later) of SIMPL will not affect uninstalling or running older versions
of SIMPL (or vice-versa).
Allow 0's on the outputs of a JK Flip Flop (2 Series only).
SIMPL compiler: Fix COM ports so that if TX$ or RX$ is left out and signals are put on the transmit or receive side
of the com port (for triggering or matching data that is coded directly into the parameters of the port), it will trigger or
match properly. (2 Series Only).
Fixes/Changes from 2.00.18 to 2.00.22
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
Fix compilation of the UP and DOWN arrow buttons on the front panel (2 Series only)
Fix so that Application Builder can upload to a 2 Series system. This will require a newer Crestron Database (newer
than version 15.6.5), but only when using Application Builder.
SIMPL+: Fix compilation of For() loops with a negative step (2 Series only)
SIMPL+: String comparisons are now case sensitive, as they were with the X Generation. (2 Series only)
SIMPL+: Fix compilation errors for modules that contained Direct device access functions (i.e. SetSlot(), etc.) or
passing STRING_INPUT, BUFFER_INPUT, ANALOG_INPUT, or DIGITAL_INPUT variables to functions (X
Generation Only)
SIMPL+: If a 1D or 2D Integer array overflowed, the control system would crash. It now correctly reports the array
overflow (2 Series only)
SIMPL+: Fixed compilation of the NOT operator.
SIMPL+: Fixed compilation MakeString(0, ...
SIMPL+: Display message in compile output window if SIMPL+ Cross Compiler is not installed. An error message is
also printed to the SIMPL error log if the SIMPL+ cross compiler is not installed and an attempt is made to compile a
program that contains SIMPL+.
SIMPL+: Display SIMPL+ Cross Compiler version in SIMPL+ About box.
Change title on front panel editor to "Front Panel Editor" for the LCD front panel for both X Generation and 2 Series
systems.
Allow TOGGLE symbol to have "0" on it's OUT output and a signal on the OUT* output and work correctly in the
control system (2 Series only)
Clean up error message for "\\x" errors within strings in macros. "\\x" in a string must always have 2 valid hex
characters after it; the error message now prints the macro number in the main program as well as the symbol
within the macro, if the error occurred in a macro. Be aware that this holds even for partial substitution, i.e. if a string
parameter has "\\x25\\x\\[\#SECOND_BYTE\\]\\x26", that the user must type in 2 hex digits on the macro when
putting in a value for SECOND_BYTE; i.e. for 0, they need to type 00, not 0. This is not a change; just a clarification
for both X Generation and 2 Series.
Mark program as needing to be saved if a DPA card is changed from a CNXENET+ to a CNXENET or CNXENET to
CNXENET+ (X Generation Only)
Fix "TCP/IP Client" device problem when converting between an X Generation system and a 2 Series system.
Fix ST-LT operation for 2 Series systems.
Viewport: Remember last ID for remote console.
Viewport: Fix problem where exiting remote console mode on an X Generation system could fail.
Viewport: Fix problem where file system wasn't initialized on CNXENET+ card before entire web project was sent
(this resulted in duplicate files with same name in CNXENET+ card).
Viewport: Fix problem where web pages could only be sent to a PRO2 and no other 2-series systems.