Download Carrier 060 Unit installation

Transcript
Fig. 10 - Typical Aquazone Complete C control wiring (three-phase unit)
PB
6
Power supply
Refer to data plate
Use copper
conductors only
Earth (GRD)
5
N (Neutral)
4
Lug
LUG
L2
2
L1
1
T3
T2
T1
CC
G/Y
Ground lug
BLK L3
3
L3
Component location
G/Y
G/Y
BLK
T3
BLK
CC
BLK L2
T2
BLK
T3
T1 Compr.
T2
BLK L1CC T1
BLK
BLK
BLK
YEL
See note 3
CB* TRANS
BR1
BR2
BLK
H
BLU
YEL OR
BM M
WHT
RED
L
BRN
BLK
RED
(220V)
PB
7
See note 2
ORG
(240V)
BR2
8
6
See note 7
1
CXM
TRANS
0
BR
CC
GRY
BRN
BR
BRG
BRN YEL
See note 7
CC
CCG
C
Test pins
Typical
T-stat
Compr.
Y
See
note 4
O
Fan
G
24 V a.c.
Common
C
Alarm
L
See note 6 for
dry alarm contact
Dip switch
JW3
FP1
W
1
2
3
4
5
Low temp.
JW2
FP2
O
G
Low temp.
R
On
ON
G
Status
LED
C
RED
3
LOC
4
BLU
5
6
GRY
FP1
FP2
7
8
RV 9
10
AL2
Alarm
relay
HP
RED
LOC
BRN
See note 4
GRY
VIO
Cap. tube VIO
(
units
VIO
FP1
TXV units
BRN
ORG
FP2
RVS
Not used
JW1
AL1
A
P1
PM
Stages
Not used
Not used
1 or 3
Tree
Off
OFF
1
2
HP
Y
Y
Cooling
R
Compressor
relay
R
See note 5
CXM
Microprocessor
control logic
See
note 5
CO 12
P2
YEL
CO
24V
DC
EH1
CO
Legend
AL
BR
CAP
CB
CC
CO
COMP
FP1
FP2
GND
HP
JW
LOC
P1
PB
Alarm relay contacts
Blower relay
Compressor capacitor
Circuit breaker
Compressor contactor
Sensor, condensate overflow
Compressor
Sensor, water coil freeze protection
Sensor, air coil freeze protection
Ground
High pressure switch
Clippable field selection jumper
Loss of charge pressure switch
Field wiring terminal block
Power block
PM
PSC
RVS
TRANS
Performance Monitor
Permanent split capacitor
Reversing valve solenoid
Transformer optional wiring
Field line voltage wiring
Field low voltage wiring
Printed circuit trace
Optional wiring
Relay/contactor coil
Thermistor
EH2
P3
Condensate pan
Circuit breaker
Relay contacts - NC
Solenoid coil
Relay contacts - NO
Switch temperature
Switch low pressure
Ground
Wire nut
Splice cap
* Optional wiring
Notes:
1. Compressor and blower motor thermally protected internally.
2. All wiring to the unit must comply with local codes.
3. Transformer is wired to 240 V (ORG) lead for 240-1-50 units, switch RED and
ORG leads to PB(3) and insulate ORG lead.
4. FP1 thermistor provides freeze protection for water. When using anti-freeze
solutions, cut JW3 jumper.
5. Typical heat pump thermostat wiring shown. Refer to thermostat installation
instructions for wiring to the unit.
12
6.
7.
8.
24-V alarm signal shown. For dry alarm contact, cut JW1 jumper, and dry
contact will be available between AL1 and AL2.
Transformer secondary ground via microprocessor board stand-offs and
screws to control box. (Ground available from top two stand-offs as shown.)
Fan motors factory-wired for medium speed. For high or low speed remove
BLU wire from fan motor speed tap ‘M’ and connect to ‘H’ for high or ‘L’ for low.