Download Carrier 060 Unit installation
Transcript
Fig. 10 - Typical Aquazone Complete C control wiring (three-phase unit) PB 6 Power supply Refer to data plate Use copper conductors only Earth (GRD) 5 N (Neutral) 4 Lug LUG L2 2 L1 1 T3 T2 T1 CC G/Y Ground lug BLK L3 3 L3 Component location G/Y G/Y BLK T3 BLK CC BLK L2 T2 BLK T3 T1 Compr. T2 BLK L1CC T1 BLK BLK BLK YEL See note 3 CB* TRANS BR1 BR2 BLK H BLU YEL OR BM M WHT RED L BRN BLK RED (220V) PB 7 See note 2 ORG (240V) BR2 8 6 See note 7 1 CXM TRANS 0 BR CC GRY BRN BR BRG BRN YEL See note 7 CC CCG C Test pins Typical T-stat Compr. Y See note 4 O Fan G 24 V a.c. Common C Alarm L See note 6 for dry alarm contact Dip switch JW3 FP1 W 1 2 3 4 5 Low temp. JW2 FP2 O G Low temp. R On ON G Status LED C RED 3 LOC 4 BLU 5 6 GRY FP1 FP2 7 8 RV 9 10 AL2 Alarm relay HP RED LOC BRN See note 4 GRY VIO Cap. tube VIO ( units VIO FP1 TXV units BRN ORG FP2 RVS Not used JW1 AL1 A P1 PM Stages Not used Not used 1 or 3 Tree Off OFF 1 2 HP Y Y Cooling R Compressor relay R See note 5 CXM Microprocessor control logic See note 5 CO 12 P2 YEL CO 24V DC EH1 CO Legend AL BR CAP CB CC CO COMP FP1 FP2 GND HP JW LOC P1 PB Alarm relay contacts Blower relay Compressor capacitor Circuit breaker Compressor contactor Sensor, condensate overflow Compressor Sensor, water coil freeze protection Sensor, air coil freeze protection Ground High pressure switch Clippable field selection jumper Loss of charge pressure switch Field wiring terminal block Power block PM PSC RVS TRANS Performance Monitor Permanent split capacitor Reversing valve solenoid Transformer optional wiring Field line voltage wiring Field low voltage wiring Printed circuit trace Optional wiring Relay/contactor coil Thermistor EH2 P3 Condensate pan Circuit breaker Relay contacts - NC Solenoid coil Relay contacts - NO Switch temperature Switch low pressure Ground Wire nut Splice cap * Optional wiring Notes: 1. Compressor and blower motor thermally protected internally. 2. All wiring to the unit must comply with local codes. 3. Transformer is wired to 240 V (ORG) lead for 240-1-50 units, switch RED and ORG leads to PB(3) and insulate ORG lead. 4. FP1 thermistor provides freeze protection for water. When using anti-freeze solutions, cut JW3 jumper. 5. Typical heat pump thermostat wiring shown. Refer to thermostat installation instructions for wiring to the unit. 12 6. 7. 8. 24-V alarm signal shown. For dry alarm contact, cut JW1 jumper, and dry contact will be available between AL1 and AL2. Transformer secondary ground via microprocessor board stand-offs and screws to control box. (Ground available from top two stand-offs as shown.) Fan motors factory-wired for medium speed. For high or low speed remove BLU wire from fan motor speed tap ‘M’ and connect to ‘H’ for high or ‘L’ for low.