Download Ericsson Dialog 3146 User`s guide

Transcript
FACILITY DESCRIPTION
Uppgjord/Prepared
Faktaansvarig - Subject responsible
5(31)
Dokumentnr/Documentnr
265/155 34-ASB 150 02 Uen
Dokansv/Godkänd - Doc respons/Approved
Kontr/Checked
Datum/Date
Rev
99-07-15
Tillhör/Referens-File/Reference
C
Commands via RASC
See document TANDEM CONFIGURATION, 480 / 155 34 - ASB 150 02 Uen
Following commands have to be programmed for installing Integrated Cordless:
2061 - 2065
Priority link for synchronisation
These commands define which link will have the first /second /third /fourth /fifth priority to be master.
The IC-CU_ has to be included in one of these commands:
•
ISDN trunks are connected to ASB 150 02 => state the IC-CU_ board for the last priority
•
Only Analogue trunks are connected to ASB 150 02 => state the IC-CU_ board for the first priority
valid data: 01 000 - 56 000
default data: Empty
0172
Diversion on not available internal
Only available using the GAP protocol !
This command is used to activate diversion on not available for internal calls. Diversion on not available is a result of
a not available cordless. If no diversion address is specified the diversion is inactive.
10 Jul 14:40
+15˚
DIV NOT AVAIL INT.
backward
forward
0172
xxxx
c/i
>
return
xxxx
Enter common directory number
Press ENTER
10 Jul 14:40
backward
+15˚
zzzzzzzz
0172
forward
c/i
xxxx
return
zzzzzzzz
Enter diversion address
Note: After a call diversion "on not available" no repeated call diversion is possible any more.