System details/functions Summary (cont.) Setting (as delivered condition) Setting range Explanation 0 to 3 0: Maximum cylinder temperature control deactivated Solar circuit pump is controlled in accordance with selected start-up and shutdown temperature differential 1: Maximum cylinder temperature control activated 2: Maximum cylinder temperature deactivated, reverse cooling function activated (see pageĂ26) 3: Maximum cylinder temperature control activated with a lower priority, collector cooling function activated (see pageĂ25) FNĂćĂFunction FXĂćĂMaximum volume flow 0 Adjusting the volume flow in accordance to with the collectors used Vitosol service instructions 20Ăl/min MEĂćĂHeat transfer medium 0 and 1 0: Water 1: TyfocorĆĂLS 0 to 4 0:ĂRelayĂ1 and 2 OFF 1:ĂRelayĂ1 ON, RelayĂ2 OFF 2:ĂRelayĂ1 OFF, RelayĂ2 ON 3:ĂRelayĂ1 and 2 ON 4:ĂAutomatic mode 5862Ă490ĂGB MMĂćĂManual mode 20