Download Bosch 28i RSF Technical data
Transcript
Contents 1. Installation Regulations . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 2. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 3. Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 4. Siting the Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 5. Siting the Flue. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 6. Air Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7. Sealed System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 8. Open Vent System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 9. Domestic Hot Water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 10. Gas Suppy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 2 2 4 6 7 7 8 8 9 9 11. Electrical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 10 12. Installing the Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . Page 13 13. Commissioning the Appliance . . . . . . . . . . . . . . . . . . . . Page 18 14. Handover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 20 15. Inspection and Service . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 21 16. Replacement of Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 22 17. Operational Flow Diagrams. . . . . . . . . . . . . . . . . . . . . . . Page 27 18. Fault Finding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 29 19. Component Parts List. . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 37 1. Installation Regulations 2. Introduction 1.1 Gas Safety (Installation and Use) Regulations, October 1998 All gas appliances must be installed by a competent person in accordance with the above regulations. Failure to install appliances correctly could lead to prosecution. 1.2 The manufacturers notes must not be taken, in any way, as overriding statutory obligations. 1.3 The compliance with a British Standard does not, of itself, confer immunity from legal obligations. In particular the installation of this appliance must be in accordance with the relevant requirements of the following; Gas Safety (Installation and Use) Regulations 1998 as amended. Current IEE Wiring Regulations BS 7671. Local Building Regulations. Building Standards (Scotland)(Consolidation). Bylaws of the local Water Company. Health and Safety Document No. 635 (Electricity at Work Regulations). The British Gas Material and Installation Specification for central heating and hot water It should be in accordance with the relevant recommendations of the following British Standards. BS6798:1987 Specification for installation of gas fired hot water boilers of rated input not exceeding 60 kW. BS5449:1990 Central Heating for Domestic Premises. BS5546:1990 Installation of gas hot water supplies for domestic purposes. BS5440:1:2000 Flues and Ventilation for gas appliances of rated input not exceeding 60 kW: Flues. BS5440:2:2000 Flues and Ventilation for gas appliances of rated input not exceeding 70kW: Air Supply. BS6891:1988 Installation of low pressure gas pipework installations up to 28mm (R1). BS7593:1993 Central Heating system cleansing and flushing. 1.4 To ensure that the installation will perform to the highest standards, the system and components should conform to any other relevant British Standards in addition to those mentioned in the instructions. 1.5 The appliance complies with the Essential Requirements of the Gas Appliance Directive and other Directives currently applicable. 1.6 This appliance contains no asbestos products. There is no potential hazard due to the appliance being electrically unsafe. There are no substances used that are a potential hazard in relation to the COSHH Regulations 1988. 1.7 The advice and instructions given in this document covers, as far as possible, the foreseeable situations which may arise. Contact Worcester Heat Systems Technical Helpline for advice on specific installations. 1.8 Product Liability regulations indicate that, in certain circumstances, the installer can be held responsible, not only for mistakes on his part but also for damage resulting from the use of faulty materials. We advise that, to avoid any risk, only quality approved branded fittings be used. The Benchmark initiative is the new code of practice to encourage the correct installation, commissioning and servicing of domestic central heating boilers and system equipment. The 'Log-book' is a vital document that must be completed by the installer at the time of installation. It confirms that the boiler has been installed and commissioned according to the manufacturers instructions. Without the completion of the Log-book, manufacturers may refuse to respond to a call-out from a householder, who will be advised that he or she must call back the installer, who has not fulfilled his obligations to record the information required by the initiative. It is important that: The services and the system are properly flushed as specified. The User is clearly instructed on the correct operation of the appliance. The benefits of regular servicing are explained - to maintain the efficiency and extend the life of the appliance. 2.1 General Information The appliance is set to give the maximum output of 27.5 kW to the domestic hot water and to the heating system. The hot water flow rate is limited to a nominal 10 l/min at a maximum temperature rise of 40°C. The sanitary water section of the appliance is suitable for mains water pressure of up to 10bar. 2.2 Electrical Supply 230V - 50Hz. Load 180 watts. External fuse 3A, Internal fuses F1 - 2A, F2 - 1.0A (20mm). 2.3 Gas supply The appliance requires a maximum of 3.17 m3/h of natural gas (G20). The installation and the connection of the gas supply to the appliance must be in accordance with BS6891. The meter or regulator should deliver a dynamic pressure of 20 mbar (G20) at the appliance, which is equivalent to about 1919.5 mbar at the gas valve inlet pressure test point. 2.4 Installation The appliance is suitable for indoor installation only and for use with a sealed system only. Do not place anything on top of the appliance. It is a room sealed appliance and a separate combustion air supply is not required in any room or compartment in which the appliance is fitted. If the appliance is fitted in a cupboard or a compartment is built around it after installation, then the structure must conform to the requirements of BS6798 and BS5440 Part 2. However, because of the low casing losses, there is not a need for the cooling ventilation openings in the compartment. The spaces specified in Section 6.3 must be maintained. There is space for the service pipes to pass at the back of the appliance. 2.5 Flue The appliance has a multi-directional fanned flue system. The standard telescopic flue assembly length is from 330mm to 725mm. Extension flue kits are available for flue lengths up to 2500mm. 2