Download Christie LW600 Serial Communications Protocol

Transcript
Status Read Commands
8.4.16 CF_IMAGEADJ Command
Command
%1
“CF_IMAGEADJ_%1”[CR]
“RST”- Reset adjusted value for the Image
“STR1”- Store current adjusted value to Image 1
“STR2”- Store current adjusted value to Image 2
“STR3”- Store current adjusted value to Image 3
“STR4”- Store current adjusted value to Image 4
“STR5”- Store current adjusted value to Image 5
“STR6”- Store current adjusted value to Image 6
“STR7”- Store current adjusted value to Image 7
“STR8”- Store current adjusted value to Image 8
“STR9”- Store current adjusted value to Image 9
“STR10”- Store current adjusted value to Image 10
Detail
Reset or Store adjusted value for Image (available only in the normal
Power ON status).
“STR1”-”STR10” corresponds to “Image1”-”Image10” displayed in
projector OSD menu on selecting
“Store” for adjusted value of Image. The setting value set in
“Image1” to “Image10” is stored and can be retrieved when turning
on the projector again after the power is turned to ALL OFF status.
Response
8.5
Acceptable
“000” [CR]
Unacceptable
“Error Code” [CR]
PC Control Command
8.5.1 CF_FSYNC Command
Command
“CF_FSYNC_%1” [CR]
%1
“0000-0031” - Directly specify setting value of Fine Sync
“UP” - Increment setting value of Fine Sync by 1
“DN” - Decrement setting value of Fine Sync by 1
Detail
Set value of Fine Sync in PC signal (available only in the normal
Power ON status).
The value set by this command is not stored in the projector’s
memory. Therefore, when the power is turned to ALL OFF status, the
value returns to the original setting. (It is stored in Suspend mode.)
Response
Acceptable
“000” [CR]
Unacceptable
“101” [CR]
When input is Video signal
When input is no signal
8-8
LW600-LX900-LX1000 RS232 Codes-Expanded Technical Reference Information
020-000046-02 Rev 2 (07-2011)