Download Carrier 48TC*D08 Specifications
Transcript
Table 23 – Troubleshooting Alarms Safety Chain Alarm safety_chain Fire Shutdown Alarm fire_alarm Space Temp Sensor Failure spt_alarm SAT Sensor Alarm sat_alarm High Space Temp Alarm spt_hi Alarm Generated Automatic Low Space Temp Alarm spt_lo Alarm Generated Automatic High Supply Air Temp sat_hi Alarm Generated Automatic Low Supply Air Temp sat_lo Alarm Generated Automatic Supply Fan Failed to Start sf_fail Supply Fan in Hand sf_hand Compressor Safety Alarm dx_compstat Setpoint Slider Alarm slide_alarm Dirty Filter Alarm filter ACTION TAKEN BY CONTROL Alarm Generated Immediate Shutdown Alarm Generated Immediate Shutdown Alarm Generated Immediate Shutdown Alarm Generated Immediate Shutdown Alarm Generated Immediately disable Operation Alarm Generated Ramp down Operations RESET METHOD Automatic Over load Indoor Fan or Electric Heater overheat. Automatic Smoke detected by smoke detector or configuration incorrect Automatic Faulty, shorted, or open thermistor caused by wiring error or loose connection. Automatic Faulty, shorted, or open thermistor caused by wiring error or loose connection. Automatic The space temperature has risen above the cool setpoint by more than the desired amount. The space temperature has dropped below the heat setpoint by more than the desired amount. SAT is greater then 160 degrees for more than 5 minutes. The supply air temperature is below 35_F for more than 5 minutes. Tripped Circuit Breaker, Broken belt, Bad indoor fan motor, Configuration incorrect, Bad fan status switch. Automatic Bad Fan Status Switch, Configuration incorrect. Alarm Generated Automatic Compressor would not start. Alarm Generated Offset set to zero Automatic STO sensor is open or shorted for more then 5 seconds. Alarm Generated Alarm Generated Disable misconfigured switch functions Alarm Generated Disable 4 selectable analog inputs Alarm Generated Economizer and Low ambient DX cooling lockout disabled. Alarm Generated Dehumidification disabled Automatic/re set timer when configured with or without switch Dirty Filter, supply fan run time exceeded, filter switch configuration wrong. Configure correctly More than one binary input is configured for the same purpose. More then one discrete input is configured to provide the same function. Configure correctly More then one analog input is configured to provide the same function. Automatic Faulty, shorted, or open thermistor caused by wiring error or loose connection. Automatic Sensor reading is out of range. Bad sensor, bad wiring, or sensor configured incorrectly. Switch Configuration Alarm sw_cfg_alarm Misconfigured Analog Input an_cfg_alarm OAT Sensor Alarm oat_alarm Space RH Sensor Alarm sprh_alarm Outdoor RH Sensor Alarm oarh_alarm Alarm Generated Automatic High Space Humidity sprh_hi Alarm Generated Automatic Low Space Humidity sprh_lo Automatic IAQ Sensor Alarm iaq_alarm OAQ Sensor Alarm oaq_alarm Alarm Generated Alarm Generated Disables IAQ Operation Economizer moves to minimum position Alarm Generated Set OAQ to 400 co2_hi Alarm Generated sf_rntm Alarm Generated dx1_rntm Alarm Generated dx2_rntm Alarm Generated High Carbon Dioxide Level Supply Fan Runtime Alarm Compressor 1 Runtime Alarm Compressor 2 Runtime Alarm PROBABLE CAUSE Sensor reading is out of range. Bad sensor, bad wiring, or sensor configured incorrectly. IRH is greater then 70% for more then 10 minutes. IRH is less then 35% for more then 10 minutes. Automatic Sensor reading is out of range. Bad sensor, bad wiring, or sensor configured incorrectly. Automatic Sensor reading is out of range. Bad sensor, bad wiring, or sensor configured incorrectly. Automatic CO2 reading is above 1200ppm. clear the timer clear the timer clear the timer 53 Supply fan run time exceeded user defined limit. Compressor run time limit is exceeded. Compressor run time limit is exceeded. 48TC POINT NAME BACnet OBJECT NAME