6-86 Drive Control MPH-02, MPB-02, MPD-02 Minimum Voltage for Power Output In the case of power output of the DC bus and correct mains voltage, the minimum value of the DC bus voltage for signaling the readiness for power output ... • in the case of supply units, 75% of the crest value of the mains voltage detected when switching on (cannot be set), • in the case of converters, 75% of the crest value of the mains voltage detected when switching on, unless a higher minimum value has bee set via P-0-0114, Undervoltage threshold. In case the voltage value has fallen below the minimum voltage, the error message F2026 Undervoltage in power section is generated and power is switched off. Note: Power Off The crest value of the mains voltage is detected when the mains contactor is activated. It is displayed in parameter P-0-0815, Nominal mains voltage crest value (only for converters, not for supply units). In the case of error power is switched off automatically, • in the case of supply units, by switching the integrated mains contactor off, • in the case of converters, by opening the "Rel1" contact that has to be available in the switch-off path of the mains contactor. Note: Therefor the status information "supply ready for operation" (respective bit in P-0-0861, Status word of power section) has to be assigned to the "Rel1" contact of the control section for converters; no other signal may be assigned to this contact. Otherwise power is not switched off automatically! Depending on the hardware-side design and control of the supply unit or converter, "DC bus short circuit" (for decelerating synchronous motors) can be activated, too. Note: Recommendations on the hardware-side control of supply units or converters are contained in the documentation of the respective device. Criteria for power off (for supply units) or opening the "Rel1" contact (for converters): • error in supply (see "Supply Error Messages" in section "Diagnostic and Status Messages") • fatal error in inverter or converter (F8xxx), is signaled at supply unit by corresponding configuration of the inverter or converter as regards power supply (P-0-0118) • charged DC bus has fallen below "minimum voltage for power output" (see above) Note: When an inverter signals missing readiness for operation to the module bus, power is not switched off when DC bus is ready for power output (exception see above "fatal error... (F8xxx), ...")! DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Related documents
ROBBE BLUE ARROW XL 490 Operating instructions
Projektierungsanleitung
VASS New User Manual 2014 - Victorian Curriculum and
Installation Instructions
PL SERIES with Safeseal™ Gasket SÉRIES PL SERIE PL
MM HA16 NG GB.book
HA20_26 GB Maintenance.backup.book
Micromaxx MM 2854 Operating instructions
Dok CR12 Technical data
Functional Description Manual
Carrier Access BROADway System 770-0125-AB Operating instructions