Transcript
Operation and Features DRAFT Case 1 - Exposure Start With Frame Valid High Timing charts are not drawn to scale. Figure 3-6: ExSync, Programmable Mode - Exposure Start with Frame Valid High If the ExSync signal rises while frame valid is high as shown in Figure 3-6: • The actual start of exposure can be up to 25 µs later than the rise of the ExSync signal. (This is commonly referred to as an exposure start jitter.) • The actual length of the exposure time will be equal to the programmed exposure time plus 77.7 µs minus the jitter time. L 3-8 As shown in Figure 3-6, FVAL must be low for at least 1 µs before the programmed exposure time ends. BASLER A202k