PERIMETER CLEARANCES All units Left side minimum 50mm (2”) Left side 201/202 electric unit min. 500 mm (20“) Left side recommended for all units for service or with adjacent heat source 500 mm (20“) Rear side 50mm (2”) Right side 50mm (2”) Measured space Drain connection YES NO S Levelling and Floor fixing (observe local codes!) COMMON Steam temperature resistant pipe (I.e. Part # 8720.1031) (Flexible hose connection NOT permitted) Table unit with P-trap or open drain Floor unit with P-trap or open drain (open drain end not under unit) Combi Duo connected with separate P-trap or open drain for each unit YES NO YES NO Electric 61, 62, 101, 102 Mounting surface is level? Unit is level? Gas 61, 62, 101, 102 Mounting surface is level? Stand is fixed to the floor Unit is secured to mounting surface? Electric and Gas 61, 62, 101, 102 Transport trolley is level with unit and stand is fixed to the floor ? (when mobile oven rack is used) Electric and Gas 201, 202 Unit is level? Unit is fixed to the floor? (use part # 8700.0317) Area under unit level? Trolley stands level inside the unit? Water connection Cold water service shut off valve for each unit? Shut off valve accessible from front by operator Pressure reduction valve set at 350 kpa(3,5bar, 51psi) All units: Min: 150 kpa (1,5 bar, 22 psi,) Max 600 kpa (6bar, 88psi) Water filtration / treatment system installed? Manufacturer and type of water filter Actual measured water pressure (after filter): -101-