CS4265
2. CHARACTERISTICS AND SPECIFICATIONS
SPECIFIED OPERATING CONDITIONS
AGND = DGND = 0 V; All voltages with respect to ground.
Parameters
DC Power Supplies:
Symbol
Min
Nom
Max
Units
VA
VD
VLS
VLC
TA
3.13
3.13
1.71
1.71
-10
5.0
3.3
3.3
3.3
-
5.25
(Note 1)
5.25
5.25
+70
V
V
V
V
C
Analog
Digital
Logic - Serial Port
Logic - Control Port
Ambient Operating Temperature (Power Applied)
Notes:
1. Maximum of VA+0.25 V or 5.25 V, whichever is less.
ABSOLUTE MAXIMUM RATINGS
AGND = DGND = 0 V All voltages with respect to ground. (Note 2)
Parameter
Symbol
Min
Max
Units
VA
VD
VLS
VLC
Iin
-0.3
-0.3
-0.3
-0.3
+6.0
+6.0
+6.0
+6.0
V
V
V
V
-
10
mA
VINA
AGND-0.3
VA+0.3
V
VIND-S
VIND-C
-0.3
-0.3
VLS+0.3
VLC+0.3
V
V
Ambient Operating Temperature (Power Applied)
TA
-50
+125
C
Storage Temperature
Tstg
-65
+150
C
DC Power Supplies:
Input Current
Analog
Digital
Logic - Serial Port
Logic - Control Port
(Note 3)
Analog Input Voltage
Digital Input Voltage
Logic - Serial Port
Logic - Control Port
2. Operation beyond these limits may result in permanent damage to the device.
Normal operation is not guaranteed at these extremes.
3. Any pin except supplies. Transient currents of up to ±100 mA on the analog input pins will not cause
SCR latch-up.
DS657F3