CS4265 2. CHARACTERISTICS AND SPECIFICATIONS SPECIFIED OPERATING CONDITIONS AGND = DGND = 0 V; All voltages with respect to ground. Parameters DC Power Supplies: Symbol Min Nom Max Units VA VD VLS VLC TA 3.13 3.13 1.71 1.71 -10 5.0 3.3 3.3 3.3 - 5.25 (Note 1) 5.25 5.25 +70 V V V V C Analog Digital Logic - Serial Port Logic - Control Port Ambient Operating Temperature (Power Applied) Notes: 1. Maximum of VA+0.25 V or 5.25 V, whichever is less. ABSOLUTE MAXIMUM RATINGS AGND = DGND = 0 V All voltages with respect to ground. (Note 2) Parameter Symbol Min Max Units VA VD VLS VLC Iin -0.3 -0.3 -0.3 -0.3 +6.0 +6.0 +6.0 +6.0 V V V V - 10 mA VINA AGND-0.3 VA+0.3 V VIND-S VIND-C -0.3 -0.3 VLS+0.3 VLC+0.3 V V Ambient Operating Temperature (Power Applied) TA -50 +125 C Storage Temperature Tstg -65 +150 C DC Power Supplies: Input Current Analog Digital Logic - Serial Port Logic - Control Port (Note 3) Analog Input Voltage Digital Input Voltage Logic - Serial Port Logic - Control Port 2. Operation beyond these limits may result in permanent damage to the device. Normal operation is not guaranteed at these extremes. 3. Any pin except supplies. Transient currents of up to ±100 mA on the analog input pins will not cause SCR latch-up. DS657F3 9