Appendix B: Product Certifications
Reference Manual
00809-0100-4107, Rev BA
June 2013
European Certifications
I1
ATEX Intrinsic Safety
Certificate No: Baseefa08ATEX0129X
Applicable Standards: EN60079-0:2012, EN60079-11:2012
Markings:
II 1 G Ex ia IIC T4 Ga(–60 °C  Ta  +70 °C)
IP66 IP68
1180
Table B-3. Input Parameters
Ui = 30 V
Ii = 300 mA
Pi = 1.3 W
Ci = 0 μF
Special Conditions for Safe Use (X):
When the optional transient protection terminal block is installed, the apparatus is not
capable of withstanding the 500 V insulation test required by Clause 6.3.12 of
EN60079-11. This must be taken into account when installing the apparatus.
IA
ATEX FISCO Intrinsic Safety
Certificate No: Baseefa08ATEX0129X
Applicable Standards: EN60079-0:2012, EN60079-11:2012
Markings: II 1 G Ex ia IIC T4 Ga(–60 °C < Ta < +60 °C)
IP66 IP68
1180
Table B-4. Input Parameters
Ui = 30 V
Ii = 200 mA
Pi = 1.0 W
Ci =  0.012 μF
Special Conditions for Safe Use (X):
When the optional transient protection terminal block is installed, the apparatus is not
capable of withstanding the 500 V insulation test required by Clause 6.3.12 of
EN60079-11. This must be taken into account when installing the apparatus.
N1
ATEX Type n
Certification No. Baseefa08ATEX0130X
Applicable Standards: EN60079-0:2012, EN60079-15:2010
Markings:
II 3 G
Ex nA IIC T4 Gc (–40 °C  Ta  +70 °C)
Ui = 42.4 Vdc max
IP66
Special Conditions for Safe Use (X):
When the optional transient protection terminal block is installed, the apparatus is not
capable of withstanding a 500 V r.m.s. test to case. This must be taken into account on
any installation in which it is used, for example by assuring that the supply to the
apparatus is galvanically isolated.
176