Download Conair MPW User guide

Transcript
 flow rate must change at a rate of no greater than 10% per minute in order to maintain an acceptable level of temperature control. This is a practical amount of water which typically buffers fluctuations in the process enough that the chiller will generally see fairly gradual rates of change in the inlet water temperature and will be able to accurately load or unload the compressor(s) which in turn will allow for very consistent and stable supply temperatures to the process. Use a system volume of 6 to 10 gallons of coolant per ton (6.4 to 10.8 L per kW) if the flow rate changes more rapidly than 10% per minute. If the chiller sees a net rate of change greater than 10% per minute it may result in temporary supply temperature fluctuations greater than 1°F (0.5°C). Table 2 – Chiller Flow Rate Limitations
Chiller Model EP2A‐04 EP2R‐04 EP2A‐05 EP2R‐05 EP2A‐08 EP2R‐08 EP2A‐10 EP2R‐10 EP2A‐13 EP2A‐15 EP2R‐15 EP2A‐20 EP2R‐20 EP2A‐25 EP2R‐25 EP2A‐30 EP2R‐30 EP2A‐35 EP2R‐35 EP2A‐40 EP2R‐40 EP2W‐05 EP2W‐08 EP2W‐10 EP2W‐15 EP2W‐20 EP2W‐25 EP2W‐30 EP2W‐35 EP2W‐40 Minimum Flow
gpm (lpm) psi (kPA)
4.9 (18.5) 1.5 (10.2)
4.9 (18.5) 1.5 (10.2)
5.9 (22.1) 1.9 (13)
5.9 (22.1) 1.9 (13)
8.6 (32.4) 1.6 (11.2)
8.6 (32.4) 1.6 (11.2)
12.8 (48.4) 2.7 (18.3)
12.8 (48.4) 2.7 (18.3)
14.7 (55.6) 2.4 (16.5)
17.3 (65.5) 2.1 (14.7)
17.3 (65.5) 2.1 (14.7)
23 (87.1) 2.5 (17)
23 (87.1) 2.5 (17)
29.2 (110.4) 1.9 (13.3)
29.2 (110.4) 1.9 (13.3)
34.6 (130.8) 2.2 (15.4)
34.6 (130.8) 2.2 (15.4)
40 (151.2) 1.9 (13)
40 (151.2) 1.9 (13)
45.4 (171.7) 2 (14.1)
45.4 (171.7) 2 (14.1)
6.4 (24) 2.2 (15.3)
9.2 (34.8) 1.9 (12.8)
14 (53) 3.2 (21.9)
18.7 (70.8) 2.5 (17.2)
25 (94.6) 2.9 (20.1)
31.5 (119.2) 2.2 (15.5)
37.2 (140.8) 2.6 (17.8)
42.7 (161.6) 2.2 (14.9)
47.6 (180.2) 2.2 (15.5)
Nominal Flow
gpm (lpm)
psi (kPA)
9.7 (36.7)
5.8 (40)
9.7 (36.7)
5.8 (40)
11 (41.6)
6.6 (45.5)
11 (41.6)
6.6 (45.5)
16.8 (63.6)
6.2 (42.7)
16.8 (63.6)
6.2 (42.7)
24 (90.8)
9.3 (64.1)
24 (90.8)
9.3 (64.1)
26.7 (101.1)
7.9 (54.5)
32.1 (121.5)
7.4 (51)
32.1 (121.5)
7.4 (51)
43.4 (164.3)
8.8 (60.7)
43.4 (164.3)
8.8 (60.7)
54.5 (206.3)
6.7 (46.2)
54.5 (206.3)
6.7 (46.2)
64.3 (243.4)
7.7 (53.1)
64.3 (243.4)
7.7 (53.1)
94.5 (357.7)
10.6 (73.1)
94.5 (357.7)
10.6 (73.1)
104.8 (396.7)
10.9 (75.2)
104.8 (396.7)
10.9 (75.2)
12.7 (48.1)
8.7 (60)
18.5 (70)
7.5 (51.7)
27.6 (104.5)
12.3 (84.8)
36.9 (139.7)
9.7 (66.9)
50.3 (190.4)
11.8 (81.4)
62.8 (237.7)
8.9 (61.4)
74.3 (281.3)
10.3 (71)
86.3 (326.7)
8.8 (60.7)
95.8 (362.6)
9.1 (62.7)
Maximum Flow
gpm (lpm) psi (kPA)
19.6 (74.2) 23.8 (163.8)
19.6 (74.2) 23.8 (163.8)
23.4 (88.6) 29.7 (204.4)
23.4 (88.6) 29.7 (204.4)
34.2 (129.4) 25.7 (176.9)
34.2 (129.4) 25.7 (176.9)
51.2 (193.8) 42.4 (292.4)
51.2 (193.8) 42.4 (292.4)
58.8 (222.6) 38.4 (264.4)
69.2 (261.9) 34.2 (235.9)
69.2 (261.9) 17.3 (65.5)
92 (348.2) 39.5 (272.5)
92 (348.2) 23 (87.1)
116.6 (441.5) 30.8 (212)
116.6 (441.5) 30.8 (212)
138.2 (523.2) 35.7 (245.7)
138.2 (523.2) 35.7 (245.7)
159.8 (605) 30.2 (208.2)
159.8 (605) 30.2 (208.2)
181.4 (686.8) 32.6 (225)
181.4 (686.8) 32.6 (225)
25.4 (96.1) 35 (240.8)
36.8 (139.3) 29.7 (204.8)
56 (212) 50.8 (349.8)
74.8 (283.1) 40 (275.6)
100 (378.5) 46.7 (321.9)
126 (476.9) 35.9 (247.5)
148.8 (563.2) 41.3 (284.8)
170.8 (646.5) 34.5 (237.9)
190.4 (720.7) 36 (247.8)
Corporate Office: 724.584.5500  Instant Access 24/7 (Parts and Service): 800.458.1960  Parts and Service: 814.437.6861
10