Download Salvis Evolino II Specifications

Transcript
6.
Unit parameters
6.1
Adjustment of operational parameters
All operational parameters are correctly set when the Combi-Steamer is delivered.
However, if it is necessary to change time and date (summer/winter time, incorrect setting)
proceed as follows:
The unit must be switched on but with no program
Set the time to 1:23 and press the key “Manual humidification“ for about 2 seconds.
Adjust the different parameters at the panel in accordance with the table below.
Display
time
Knob
Level
Pos
Description
Display
temperature
Knob
Min
Max
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
101
Hours
102
Minutes
103
Day
104
Month
105
Year
106
Format Date
107
Summer/winter time switch
108
Notation °C,°F
109
Language
110 Beep duration Program end
111 Beep duration cooking step end
112
Show Mode
113
Internal light off – door open
114
Address of appliance
115
Protocol core temperature
0
0
1
1
0
0
0
0
0
0
0
0
0
0
0
23
59
31
12
99
1
1
1
1
999
10
1
1
99
30
1
117
No Cool-Down
0
1
1
118
Disconnectible hand shower
0
1
Display
core temperature
Knob
Standard
ServicePrg
sec
sec
Adjustment
00-23
00-59
1-31
1-12
0-99
0 = DMY24; 1:DMY2
0: off; 1: Europe
0: °C ; 1: °F
0: German; 1: English
30 sec
0
0: off; 1: on
0: off; 1: on
sec
Protokoll Typ 1
0: Cool-Down enabled
1: Cool-Down disabled
1= Hand shower on
0= Hand shower off
After all parameters have been set, respectively changed, press START/STOP.
The unit is again ready for work, time display indicates 0:00 and temperature display 99°C.
- 19 -