Download Whirlpool UXD8630DYS Specifications
Transcript
INSTALLATIONINSTRUCTIONS Determine which venting method is best for your application. Vent system can terminate either through the wall or floor. Island Location - Vent System Slab Using PVC Sewer Pipe Island Location Front (Standard) Mounted Blower Motor Rear-Mounted Motor Front (Standard)-Mounted Blower Motor Blower Installed Under a Concrete B ] K Rear Mounted A. Down vent J Blower Motor B NOTE: For island locations, a front- or rear-mounted blower motor can also be mounted for right or left venting if needed for your application. Most island applications would still require the venting to be directed down through the floor. A Built-In Cabinet Locations _ K D_ E d A. B. C. D. E. Wall cap 6" (15.2 cm) round metal vent 16" (40.6 cm) maximum 6" (15.2 cm) round PVC sewer pipe 6" (15.2 cm) round metal vent transition with damper (supplied) F. 6" (15.2 cm) round PVC coupling G. Concrete slab H. I. J. K. L. M. S B II II 6" (15.2 cm) round PVC sewer pipe 6" (15.2 cm) round 90 ° PVC sewer pipe elbow Tightly pack gravel or sand completely around pipe. 6" (15.2 cm) round 90 ° PVC sewer pipe elbow 6" (15.2 cm) round PVC coupling 12" (30.5 cm) minimum II ....... C Calculating Vent System Length A. Down vent B. Left vent C. Right vent 3W' x 10" (8.3 x 25.4 cm) rectangular vent is required from the blower motor box. It can be transitioned to 6" (15.2 cm) round vent if needed. Maximum 8 Length of Vent System Vent Length 6" (15.2 cm) round 35 ft (8.9 m) 31/4"x 10" (8.3 cm x 25.4 cm) 35 ft (8.9 m)