Download Sears 153333100 Operating instructions

Transcript
FOR YOUR
SAFETY
READ
BEFORE
LIGHTING
WARNING
If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
A. This appliancehas a pilot whichmust be lightedby
hand,Whenlightingthepilot,follow theseinstructions
exactly.
B. BEFORELIGHTINGsmellall aroundtheappliancearea
for gas. Be sure to smell next to the floor because
somegasis heavierthanair andwillsetUeon thefloor.
WHATTO DOIF YOUSMELLGAS
Donottry to lightanyappliance.
Do not touch any electric switch; do not use any
phonein yourbuilding.
, Immediatelycallyourgassupplierfrom a neighbor's
phone°Followthegassupplier'sinstructions_
LiGHTiNG
D_
iNSTRUCTIONS
1oSTOP!Readthesafetyinformation
aboveon this label.
2. Removeouterdoor.
3. Set the thermostatto lowest settinq by turning the
watertemperaturedialclockwise,(( _,)to its lowest
temperaturesetting(witharrowon dial)as shown.DO
NOT FORCE.
4oTurngas controlknobclockwlse_d'l to "OFF'*position. Knob cannotbe turned from "PILOT" to "OFF"
unlessknobis depressedslightly.DO NOT FORCE.
(Figure6,page15)
5_Waitfive (5) minutesto clearout anygas°If you then
smellgas, STOP!Follow"B" in thesafety information
aboveon this label. If you don't smellgas, go to the
next step°
6oRemove(or open) inner door locatedbelow the gas
controlunit,(Figure9, page15)
7. Find pilot-followmetaltubefrom gascontrol.The pilot
is locatedon therighthandsideoftheburner°
PILOT BURNER
C.
• If you cannotreachyour gas supplier,call the fire
department.
Useonlyyour handto pushin or turnthe gascontrol
knob. Neverusetools.If the knobwill not pushin or
turn byhand,don'ttry to repairit, calla qualified service technician.Forceor attemptedrepairmay result
in a fireor explosion.
Do not use this applianceif anypart hasbeen under
water.Immedtzitely
call a qualified servicetechnician
to inspecttheapplianceandto replaceanypartof the
controlsystemand any gas controlwhichhas been
underwater.
_THERMOCOUPLE
8. If you don't smell gas,turn knobon gascontrolcounter
c!ockwise_@ to"PILOT"position. (Figure7, page15)
9o Push in control knob all the way and hold down.
Immediatelylight thepilot with a match.Continueto
hold controlknob in for aboutone (1) minuteafter
thepilot is lit. Releaseknoband it will pop backup.
Pilotshouldremainlit. If it goes out, repeatsteps 3
through8.
• If knobdoes notpop up when released,stop and
immediatelycall your servicetechnicianor gas
supplier.
' If the pilot will not stay lit after several tries,
depressand turnthegas controlknobclockwise
@ _ to "OFF'' and callyourservicetechnician
or gassupplier.(Figure6, page15)
10.Replace(or close)inner door°Replaceouter door if
doordoes not covergas controlon/offknob or temperatureadjustmentknob.(Figure9, page15)
1!. At armslength away,turngascontrolknobcounterclockwise _
to the full "ON" position.
WARNING Do not use gas control knob to regulate gas flow. (Figure8, page15)
124At armslength away,set the thermostatto desired
setting.The mark( '_') HOTindicativeof approximate
120°Fis preferredstarting point, Some local laws
may requirea lowerstartingpoint.If hotterwateris
desired,see instruction
manualand"warning" below_
13oReplacetheouterdoor if notreplacedin step10.
WARNING
Hotterwater increases the risk of scald injury°Beforechangingtemperaturesettingsee instructionmanual
TO TURN
OFF GAS TO APPLIANCE
1oSet the thermostatto lowest settingby turningthe
watertemperaturedial clockwise(F-'_) to its lowest
temperaturesetting(witharrowon dial)as shown.DO
NOT FORCE,
_
2. Turngascontrolknobclockwise_
1 to "OFF"posi.
tion. Knobcannotbe turnedfrom "PILOT" to "OFF"
unlessknobis depressedslightly_
DO NOT FORCE.
(Figure6, page15)
3_Replaceouterdoor(if removed)_