Download Benchmark DAC1 HDR Instruction manual
Transcript
Audio Precision DAC2 - FFT 1 kHz, 0 dBr = 0 dBFS = 23 dBu dx=.995695 kHz +0 dy=-13.022 dB +0 -20 -20 -40 -40 -60 -60 d B r -80 -80 d B r A -100 -100 A -115.268 -120 -120 -128.29 -140 -140 -160 -160 0 200 400 600 800 1k 1.2k 1.4k 1.6k 1.8k 2.00391k 2k 2.2k 2.4k 2.6k 2.8k 2.99961k 3k 3.2k Hz Sweep Trace Color Line Style Thick Data Axis 1 1 1 2 Green Red Solid Solid 4 4 Fft.Ch.1 Ampl Fft.Ch.2 Ampl Left Right Comment Cursor1 Cursor2 *-115.268 dBr -115.954 dBr A *-128.290 dBr -130.429 dBr A DAC2 - FFT 1 kHz.at27 Graph Plot 4 - FFT 1 kHz The 1 kHz FFT analysis demonstrates the low harmonic distortion of the DAC2. Second harmonic distortion (2 kHz) measures about -115 dB, while 3rd harmonic distortion measures -128 to -130 dB. The rise at 0 Hz is normal in an FFT analysis and is not an indication of noise. This 32k point FFT analysis uses a Blackman-Harris window with 16x power averaging, and spans a frequency range of DC to 32 kHz. DAC2 Series Instruction Manual Rev C Page 43