DAC2 - FFT 1 kHz.at27
Graph Plot 4 - FFT 1 kHz
The 1 kHz FFT analysis demonstrates the low harmonic distortion of the DAC2. Second harmonic
distortion (2 kHz) measures about -115 dB, while 3rd harmonic distortion measures -128 to -130
dB.
The rise at 0 Hz is normal in an FFT analysis and is not an indication of noise. This 32k point FFT
analysis uses a Blackman-Harris window with 16x power averaging, and spans a frequency range
of DC to 32 kHz.
DAC2 Series Instruction Manual
Rev C
Page 43