Fountain Troubleshooting Guide
Troubleshooting Guide
WARNING: Inspection, testing, and repair of electrical equipment should be performed only by
qualified service personnel. The unit should be
unplugged when servicing, except when electrical tests are required.
DANGER: Use extreme care during electrical circuit tests. Live circuits may be exposed.
Section 8: Syrup System (continued)
Qualifier
No syrup of insufficient
Syrup in finished drink.
(continued)
Drinks too sweet.
Peculiar taste.
Probable Cause
Gas leak at Syrup System.
Corrective Action
Use a soap solution around all connections,
starting from the Low and Medium Pressure
Regulators to the base of the Syrup Tank Plugs,
observe Quick Disconnects, Tank Cap and Gasket, Tank Plugs and Syrup Tank O-rings for leaks.
Repair and replace if necessary.
Syrup Filter restricted.
Disengage Syrup Quick Disconnect from the appropriate Syrup Tank. Relieve pressure at the
corresponding Dispensing valve. Remove the
Screw clamp and the Filter Screen. Wash the
Filter Screen with warm water and reassemble.
Frozen Syrup Coil.
Refer to Troubleshooting “Section 7: Refrigeration System” under No carbonated water at
any of the dispensing valves (Freeze up).
Dispensing valve inoperative.
Refer to Troubleshooting “Section 5: Dispensing Valve and Tower” under No syrup or insufficient syrup.
Low Pressure Regulator inoperative.
Verify Low Pressure Regulator set at 15 psi
(1.1 kg/cm2). Adjust Regulator if necessary. If
Regulator will not respond, repair or replace
Regulator.
Medium Pressure Regulator
inoperative.
Verify Medium Pressure Regulator set at 60 psi
(4.2 kg/cm2). Adjust Regulator if necessary. If
Regulator will not respond, repair or replace
Regulator.
Dispensing valve inoperative.
Refer to Troubleshooting “Section 5: Dispensing Valve and Tower” under Too much syrup in
finished drink.
Contaminated Syrup.
Replace tank and sanitize the system.