Figure 6.31
6.3.1 Maximum Current
A drive can deliver any level of current up to the maximum for which it is rated. This
maximum is marked on MX nameplates as Imax. This level of current is available for a short
period of time approximately 4 seconds. However, provision is made to adjust the peak
current to a lower value if some aspect of the servo-system requires it. The actual maximum
current that the drive is programmed to deliver is Ipk entered in parameter Pr42 as a
percentage of the rated Imax and determined by the equation Pr42 =
where Imax
Ipk
Ipk
x 100
Imax
= the rated maximum current of the drive, and
= the required maximum current.
The default value of Pr42 is 100 which is the rated value of Imax and will be the value of Ipk
more often than not.
Thus, maximum current Ipk is determined by the user with respect to the motor and the
application, and may be any value up to 100% of the maximum output current rating, Imax, of
the drive.