DRAWER WARMER SECTION - TROUBLESHOOTING SUGGESTIONS SYMPTOM No lights or heat (both drawers) No heat (one drawer) POSSIBLE CAUSE SUGGESTED REMEDY Hood power switch not "ON" Press power switch to "ON" NOTE: Drawer warmer is energized any time hood power switch is "ON" and Ansul® system is ready. Hood need not be operating. Temperature control not set Set for desired temperature. Damaged thermostat or heating element (RW-style units) Inspect thermostat, heating element, wiring and connections. Repair/replace as necessary. Inspect controller, temperature Damaged controller or temperature sensor, wiring and connections. sensor (RWT-style units) Repair/replace as necessary. Runaway temperature (one drawer) Food dries out Inspect cap tube for kinks or breaks. Replace thermostat. (RWT-style units) Unlikely to fail "hot" due to controller or sensor malfunction. Inspect for shorted wiring. Humidity control (air vent) not set OPEN air vent for dry operation. CLOSE air vent for moist operation. Water in pan evaporated or low Add water to pan. Food contacting water Use a Humitrol Rack Water level too high Water should be no more than 1/2" deep Humidity control (air vent) not set OPEN air vent for dry operation. CLOSE air vent for moist operation. Drawer latch catch roller not extended before closing drawer Be sure catch roller is extended before installing drawer. Drawer latch damaged Replace drawer latch Drawer stop dirty Clean and lubricate drawer stop Drawer stop damaged Replace drawer stop Food gets soggy Drawer falls open Drawer falls out when opened DRAWER WARMER 28 SV507 SvcManual WV-FG(RW)) Damaged thermostat or thermobulb capillary tube (RW-style units)