Download CNK 50 DRAKON
Transcript
IDENTIFICATION OF ELECTRICAL SYSTEM FAILURES ELECTRICAL STARTING SYSTEM DRAKON 50 NKD 7 7 Starting switch (start) • Disconnect two-way connector (1) • Connect the Tester ( ) to the connector on the side of the switch Terminal (+) Tester ➜ Red cable (2) Terminal (-) Tester ➜ Blue cable (3) • Press the “START” button 2 1 NO CONTINUITY 3 CONTINUITY Faulty starting switch ➜ Replace 8 Wiring connections • Check the ignition system for connections INCORRECT Reset see “Electrical diagram” 05188066 17 03/06 B