Download WattMaster Water Source Heat Pump Specifications

Transcript
Water Source Heat Pump Module
Installation & Wiring
Important Wiring Considerations
4. Be sure all modular wiring harness connectors are seated
firmly in their respective modular connectors on the circuit
board.
Please read carefully and apply the following information when wiring
the Water Source Heat Pump Module:
5. All wiring is to be in accordance with local and
national electrical codes and specifications.
1. To operate the Water Source Heat Pump Module in StandAlone mode, you must connect power to the 24 VAC input
terminal block. Do not allow wire strands to stick out and
touch adjoining terminals. This could potentially cause a short
circuit.
6. Check all wiring leads at the terminal block for tightness.
Be sure that wire strands do not stick out and touch adjacent
terminals. Confirm that all transducers required for your
system are mounted in the appropriate location and wired into
the correct terminals.
2. The 1 to 5 VDC signals for the Compressor modulation need
to use 18-gauge shielded twisted pair cable, and the Drain wire
must be the GND signal.
Stand-Alone Wiring
3. All 24 VAC wiring must be connected so that all ground
wires remain common. Failure to follow this procedure can
result in damage to the module and connected devices.
To operate the Water Source Heat Pump Module as Stand Alone, connect the Module to a 24 VAC power connection with an appropriate VA
rating. See Figure 3 for wiring.
OE334-23-WPM
Water Source Heat Pump
Module
NOTE: ALL RELAY OUTPUTS ARE NORMALLY
OPEN AND RATED FOR 24 VAC POWER ONLY
- 1 AMP MAXIMUM LOAD
RD
WH
BK
RELAY CONTACT RATING
IS 1 AMP MAX @ 24 VAC
COMPRESSOR A1 SUCTION
PRESSURE TRANSDUCER
COMP.
ENABLE
COMP. B2
#4 ENABLE
ALARMCOMMON
OUTPUT
RELAY
RELAY COMMON
WH
www.orioncontrols.com
BK
WH
BK
COMPRESSOR B2 SUCTION
PRESSURE TRANSDUCER
COMPRESSOR A1 ENABLE CONTACT
COMPRESSOR A2 ENABLE CONTACT
COMPRESSOR B1 ENABLE CONTACT
COMPRESSOR B2 ENABLE CONTACT
HEAT ENABLE CONTACT
WATER POF SYSTEM A CONTACT
WATER POF SYSTEM B CONTACT
BIN1
BIN2
BIN3
BIN4
BIN5
BIN6
BIN7
COM
T1
T2
GND
DIGITAL COMP. A1, A2, B1, B2
SYSTEM
- CNTRLR
C2
STAGE
1- ACOMP.
A1/B1AO1
AO1
A2
A2
OO
SYSTEM
- CNTRLR
STAGE
2 -B
COMP.
A2/B2C2
T1
T2
GND
LED NAME
STATUS
OFF MODE
1
COOLING MODE
HVAC UNIT CONNECTIONS
2
HEATING MODE
3
LED NAME
ALARM
LOW SUCTION PRESSURE
COMPRESSOR LOCKOUT
WATER FLOW FAILURE
1
2
3
LOW LEAVING WATER TEMP.
LED NAME
LEAVING WATER TEMP A
1
LEAVING WATER TEMP B
2
GROUND
WattMaster Label
#LB102069-A
Rev.: 1B
1F
COMPRESSOR A1 ENABLE
COMPRESSOR A2 ENABLE
COMPRESSOR B1 ENABLE
COMPRESSOR B2 ENABLE
ALARM OUTPUT
LED BLINK CODES
COMP. A1
ENABLE
1 ENABLE
COMP. A2
ENABLE
2 ENABLE
COMP. B1
ENABLE
3 ENABLE
COMP. B2
4 ENABLE
ENABLE
HEAT ENABLE
H2O POF
WATER
POF
#1 A
H2O POF
WATER
POF
#2 B
COMMON
E-BUS
Connector
R1
R2
R3
R4
R5
COMM
CONNECT TO CNTLR C2 TERM.
PRES
+5V
PRES
1=A1, PRES 2=A2
NOT
USED
GND
PRES
COPELAND
CNTRLR
P6
PRES 3=B1,
PRES 4=B2
GND
COPELAND
CNTRLR
P5P5
+5
NOT USED,
PRES TO P6
& GND TO
BIN 1
BIN 2
BIN 3
BIN 4
BIN 5
BIN 6
BIN 7
COM
WATTMASTER CONTROLS
4
PRES 1-4
SENSOR DETECTED
ON
NO SENSOR DETECTED
OFF
LOW SUCTION PRESSURE
1
COMPRESSOR LOCKOUT
2
E-BUS
Connector
NOTE:
OUTPUTS ARE NOT USED ON
STAND ALONE APPLICATIONS
DIP SWITCH
NOT USED FOR
STAND ALONE
APPLICATION
GND
24 VAC
RD
RD
LW: 36ºF HSP: 100 PSIG
NON-DIGITALCOMP
COMPRESSORS
NON-DIGITAL
#1 THRU #4
SUCT.
PR. SENSOR
+5V
SUCTION
+5V
PRES
1=A1, PRES 2=A2
PRES
PRESSURE
PRES
PRES
3=B1, PRES 4=B2
GND
TRANSDUCERS
+5GND
TO RED, PRES
#1 TO
thruWHT
#4 & GND TO BLK
DIGITAL COMRESSORS
DIGITAL COMP #1 THRU #4
+5V
NOT USED
WH
COMPRESSOR B1 SUCTION
PRESSURE TRANSDUCER
AAON
AAONNo.:
No.:R88350
R90680
WSHPWSHP
Protection
Module
Module
Orion
OrionNo.:
No.:OE334-23-WPM-A
OE334-23-WPM
COMPRESSOR A2 SUCTION
PRESSURE TRANSDUCER
GND
BK
R1
R1
R2
R2
R3
R3
R4
R4
R5
RC
RC
+24 VAC
RD
COMP.
ENABLE
COMP. A1
#1 ENABLE
COMP. A2 ENABLE
COMP. #2 ENABLE
COMP.
ENABLE
COMP. B1
#3 ENABLE
www.aaon.com
E
R
LEAVING WATER TEMPERATURE
FOR SYSTEM A
LEAVING WATER TEMPERATURE
FOR SYSTEM B
Figure 3: Water Source Heat Pump Module as Stand-Alone
6
Technical Guide