Water Source Heat Pump Module Installation & Wiring Important Wiring Considerations 4. Be sure all modular wiring harness connectors are seated firmly in their respective modular connectors on the circuit board. Please read carefully and apply the following information when wiring the Water Source Heat Pump Module: 5. All wiring is to be in accordance with local and national electrical codes and specifications. 1. To operate the Water Source Heat Pump Module in StandAlone mode, you must connect power to the 24 VAC input terminal block. Do not allow wire strands to stick out and touch adjoining terminals. This could potentially cause a short circuit. 6. Check all wiring leads at the terminal block for tightness. Be sure that wire strands do not stick out and touch adjacent terminals. Confirm that all transducers required for your system are mounted in the appropriate location and wired into the correct terminals. 2. The 1 to 5 VDC signals for the Compressor modulation need to use 18-gauge shielded twisted pair cable, and the Drain wire must be the GND signal. Stand-Alone Wiring 3. All 24 VAC wiring must be connected so that all ground wires remain common. Failure to follow this procedure can result in damage to the module and connected devices. To operate the Water Source Heat Pump Module as Stand Alone, connect the Module to a 24 VAC power connection with an appropriate VA rating. See Figure 3 for wiring. OE334-23-WPM Water Source Heat Pump Module NOTE: ALL RELAY OUTPUTS ARE NORMALLY OPEN AND RATED FOR 24 VAC POWER ONLY - 1 AMP MAXIMUM LOAD RD WH BK RELAY CONTACT RATING IS 1 AMP MAX @ 24 VAC COMPRESSOR A1 SUCTION PRESSURE TRANSDUCER COMP. ENABLE COMP. B2 #4 ENABLE ALARMCOMMON OUTPUT RELAY RELAY COMMON WH www.orioncontrols.com BK WH BK COMPRESSOR B2 SUCTION PRESSURE TRANSDUCER COMPRESSOR A1 ENABLE CONTACT COMPRESSOR A2 ENABLE CONTACT COMPRESSOR B1 ENABLE CONTACT COMPRESSOR B2 ENABLE CONTACT HEAT ENABLE CONTACT WATER POF SYSTEM A CONTACT WATER POF SYSTEM B CONTACT BIN1 BIN2 BIN3 BIN4 BIN5 BIN6 BIN7 COM T1 T2 GND DIGITAL COMP. A1, A2, B1, B2 SYSTEM - CNTRLR C2 STAGE 1- ACOMP. A1/B1AO1 AO1 A2 A2 OO SYSTEM - CNTRLR STAGE 2 -B COMP. A2/B2C2 T1 T2 GND LED NAME STATUS OFF MODE 1 COOLING MODE HVAC UNIT CONNECTIONS 2 HEATING MODE 3 LED NAME ALARM LOW SUCTION PRESSURE COMPRESSOR LOCKOUT WATER FLOW FAILURE 1 2 3 LOW LEAVING WATER TEMP. LED NAME LEAVING WATER TEMP A 1 LEAVING WATER TEMP B 2 GROUND WattMaster Label #LB102069-A Rev.: 1B 1F COMPRESSOR A1 ENABLE COMPRESSOR A2 ENABLE COMPRESSOR B1 ENABLE COMPRESSOR B2 ENABLE ALARM OUTPUT LED BLINK CODES COMP. A1 ENABLE 1 ENABLE COMP. A2 ENABLE 2 ENABLE COMP. B1 ENABLE 3 ENABLE COMP. B2 4 ENABLE ENABLE HEAT ENABLE H2O POF WATER POF #1 A H2O POF WATER POF #2 B COMMON E-BUS Connector R1 R2 R3 R4 R5 COMM CONNECT TO CNTLR C2 TERM. PRES +5V PRES 1=A1, PRES 2=A2 NOT USED GND PRES COPELAND CNTRLR P6 PRES 3=B1, PRES 4=B2 GND COPELAND CNTRLR P5P5 +5 NOT USED, PRES TO P6 & GND TO BIN 1 BIN 2 BIN 3 BIN 4 BIN 5 BIN 6 BIN 7 COM WATTMASTER CONTROLS 4 PRES 1-4 SENSOR DETECTED ON NO SENSOR DETECTED OFF LOW SUCTION PRESSURE 1 COMPRESSOR LOCKOUT 2 E-BUS Connector NOTE: OUTPUTS ARE NOT USED ON STAND ALONE APPLICATIONS DIP SWITCH NOT USED FOR STAND ALONE APPLICATION GND 24 VAC RD RD LW: 36ºF HSP: 100 PSIG NON-DIGITALCOMP COMPRESSORS NON-DIGITAL #1 THRU #4 SUCT. PR. SENSOR +5V SUCTION +5V PRES 1=A1, PRES 2=A2 PRES PRESSURE PRES PRES 3=B1, PRES 4=B2 GND TRANSDUCERS +5GND TO RED, PRES #1 TO thruWHT #4 & GND TO BLK DIGITAL COMRESSORS DIGITAL COMP #1 THRU #4 +5V NOT USED WH COMPRESSOR B1 SUCTION PRESSURE TRANSDUCER AAON AAONNo.: No.:R88350 R90680 WSHPWSHP Protection Module Module Orion OrionNo.: No.:OE334-23-WPM-A OE334-23-WPM COMPRESSOR A2 SUCTION PRESSURE TRANSDUCER GND BK R1 R1 R2 R2 R3 R3 R4 R4 R5 RC RC +24 VAC RD COMP. ENABLE COMP. A1 #1 ENABLE COMP. A2 ENABLE COMP. #2 ENABLE COMP. ENABLE COMP. B1 #3 ENABLE www.aaon.com E R LEAVING WATER TEMPERATURE FOR SYSTEM A LEAVING WATER TEMPERATURE FOR SYSTEM B Figure 3: Water Source Heat Pump Module as Stand-Alone 6 Technical Guide